Conveners
Operational aspects
- Marc Ross (Fermilab)
Description
- Operational aspects (commissioning, intensity ramp, machine availability)
- Risk assessment: management and tools
Michael Jonker
(CERN)
08/06/2012, 09:30
The permit based machine protection system of CLIC depends on the measured performance of the machine during the previous cycle. This presentation addresses the bootstrap procedure which, starting from safe beams, stepwise increases the beam intensities.
Andrea Apollonio
(Vienna University of Technology (AT))
08/06/2012, 11:20
In high energy accelerators the need for Protections Systems is essential to protect the machines from possible failures. As the beam energy increases, beam-induced damage can cause serious consequences in terms of repair costs and down-time of the accelerator. Hence the risk associated to a failure has to be estimated for all possible failure scenarios. The present work shows the adopted...