Speaker
esther ferrer ribas
Description
Small gap micromegas detectors (< 50 µm) are optimized for high pressure applications. Combining the microbulk manufacturing technique with a small gap can result in attractive detectors for rare event searches, in particular double beta decay or dark matter search. We will present results obtained with small gap microbulks (25 and 12.5 µm) as well as their limitations.