Conveners
Friday morning 1
- Morten Jensen (Diamond Light Source)
Dr
Shigeki Sasaki
(SPring-8/JASRI)
16/05/2014, 09:00
SPC judgements
Oral presentation
Over 15 years of operation of the SPring-8 storage ring, we encountered several
troubles in the RF system. Some of them will be picked up for the report.
As an example, we experienced the water leakage from the photon absorbers for
the synchrotron radiation to protect RF cavities.
The cause was found to be the pinholes created by corrosion of the absorber
water channel wall by the...
Salvatore Polizzo
(Brookhaven National Lab)
16/05/2014, 09:30
SPC judgements
Oral presentation
A new 9MHz RF system operating at 180KV per ring is required to increase the luminosity of low energy gold ion collisions at the Relativistic Heavy Ion Collider. In order to accommodate all planned collision energies each cavity will be required to operate between 8.7MHz and 9.4MHz while continuously providing 60KV of gap voltage. The proposed design includes a new capacitively loaded gap...
Mr
NASHAT SAWAI
(RF group SESAME)
16/05/2014, 10:00
SPC judgements
Oral presentation
The SESAME ( Synchtrone Light Source For Experimental Since And Applications in The Middle- East) Accelerator consists of a 22 MeV Microtron , and 800Mev Booster and 2.5 GeV storage Ring .