Conveners
Wednesday morning 2
- Doug Horan (Argonne National Laboratory)
-
Eric Montesinos (CERN)14/05/2014, 11:00SPC judgementsOral presentationDescription of high average Fundamental Power Coupler designed at CERN over the last 20 years. Main difficulties and power limitations. Some tips to propose better designs.Go to contribution page
-
Dr Nico Pupeter (Cryoelectra GmbH)14/05/2014, 11:30SPC judgementsOral presentationA new technique was developed to increase the efficiency of very high power RF amplifiers (50 MHz to 1.3 GHz) at a freely chosen operating point. This improvement can be achieved for a large range of output power by a remote P1-point control. The choice of the P1-point of an RF amplifier is a compromise between increased efficiency vs. increased harmonics and decreased linearity. Typically,...Go to contribution page
-
Mr Jonathan Stampe (Canadian Light Source)14/05/2014, 12:00SPC judgementsOral presentationThe Canadian Light Source synchrotron has been using the CESR-B type 500 MHz superconducting cavity for over 10 years. This presentation will discuss operating experience with these cavities to date.Go to contribution page