The beam loss monitoring system will be the main instrument charged with detecting and acting upon the majority of failures that could lead to quenches or damage. In a few cases, however, additional instrumentation is required to protect the machine. Three such systems will be discussed along with their proposed implementation,namely: the beam dump channel position interlock in IR6, a fast orbit drift interlock and a fast loss interlock using beam current transformers. For many types of failures these systems would also be a back-up to beam loss monitoring thus inceasing the overall reliability of the machine protection system.