New Generation of UV, IR and y - ray sensors with Carbon NanoTubes (CNT)

Not scheduled
10m
Auditorium & Conference Room (Other Institutes)

Auditorium & Conference Room

Other Institutes

ESADE Business School, Avenida Pedralbes, 60-62, 08034 Barcelona, Spain.

Speakers

Dr Aristotelis Kyriakis (NCSR "DEMOKRITOS")Dr Nikolaos Glezos (NCSR "DEMOKRITOS")

Description

Many types of Ultra Violet (UV) and Infrared Radiation (IR)
detectors are used up to now, based on a variety of materials depending on
the wavelength being detected. UV spectrum is of particular interest not only
in particle physics where scintillators emit in this region but also in other fields
like agriculture where the maturity of a fruit can be detected in UV(“so called
bee eye”). Concerning Chemical, Biomedical applications the use of
Medium Wavelength Infrared (MWIR) spectrum in the range 3-5 μm is
significant for gas identification and skin tumor identification but these
cameras require cooling for good resolution. On the other hand γ-ray
detectors are gas filled or solid state sensors like scintillators, silicon based
strip or pixel detectors or even CdTe and Diamond sensors.

The main idea of this proposal is to build low cost and low operating voltage
UV, IR and γ- ray sensors based on arrays of well-aligned Carbon Nano
Tubes (CNT) in the form of Single Wall CNT (SWNT) or Multi Wall CNT
(MWNT).
For the UV, IR sensor the plan is to develop a CNT layer on a Silicon
substrate and to use the hetero-junction created when CNT are grown on Si
as a
photo-detecting sensor. The Silicon substrate will be already
preprocessed with lithographic techniques to build pixels. The periphery of
each pixel will be used as electrodes to bias the pixel and get the signal out.
The advantages are: i) they can operate at Room Temperature in a wide
range of UV spectrum (200nm -400nm) and IR spectrum (from 0.8 μm to
almost 5μm), because the layer of MWNT’s covers a wide range of diameters
ii) there is no need for HV power supply since a low voltage of the order of
20V between the electrodes of the CNT pixel is enough to operate iii) matrix
arrays of CNTs can be easily grafted on a surface in a variety of scales (from
mm down to nm) by lithographically patterning a precursor and v) they are
very cheap in production. A CNT layer width of a few tenths of microns is
good enough for a UV or IR detector.
On the other hand in the case of a γ-ray detector with radiation source
localization capabilities (i.e. Compton Camera) the width of the CNT layer
required should be much bigger. This is because the main absorption
mechanism for 200KeV to 2MeV γ rays (typical range of most of the
radioactive sources) in Carbon is Compton scattering. To improve the
radiation source localization resolution it is important
to trace the recoil electron path coming from the Compton scattering in order to shrink the compton cone and estimate the source of the γ rays. Calculation show that
scattered electrons of about 1MeV are expected to travel about 2mm in
Carbon and thus this is a good detector dimension to have full charge
collection. Thus the γ-ray detector will be a pixel CNT detector based on the
same topology presented above for the UV, IR sensor of about 2mm depth
and 500μm x 500μm pixel size or even less to have enough hits to
reconstruct the electron path.
TRL level: This is quite a new area of CNT application and thus the starting
will be the study of the essential characteristics and behaviours of the CNT-Si
system followed by the development of the simulation tools (TRL1,2).
Preliminary work has shown that such kind of detectors in the UV and IR part
of the spectrum are possible. The parameters involved are the thickness of
the CNT layer, the use of a tunneling layer, the conductance of the substrate
and the use of a capping layer. Then the construction of a prototyping will
follow (TRL 3,4) and with the help of a company the extensive test of the
prototype in realistic conditions could be performed (TRL 5,6).

Summary

The main idea of this proposal is to build low cost and low operating voltage
UV, IR and γ- ray sensors based on arrays of well-aligned Carbon Nano
Tubes (CNT) in the form of Single Wall CNT (SWNT) or Multi Wall CNT
(MWNT).