Commissioning scenarios and tests for the LHC collimation system
by
MrsChiara Bracco(CERN)
→
Europe/Zurich
AB Auditorium Prevessin (CERN)
AB Auditorium Prevessin
CERN
Description
The physics reach of the LHC requires unprecedented luminosity and beam intensity in
proton-proton collisions. The maximum intensity in the LHC is directly coupled to the
maximum peak beam loss rate and the cleaning efficiency from the collimation system.
A sophisticated LHC collimation system is implemented in two cleaning insertions and
in the experimental areas. In a first phase 88 collimators are installed, being
controlled by 344 stepping motors in total. This work analyzes the achievable cleaning
efficiency with realistic imperfections, defines the required collimator settings and
establishes available tolerances for collimator setup and transient optics changes.
An optimal setup strategy can optimize cleaning efficiency, ensure passive protection,
maximize tolerances, minimize the required beam time for setup of the system and
support the expected evolution in LHC beam intensity.
Such an optimized strategy is described.