This ECR concerns a new Wall Current Transformer (BCTW) requested by the LIU-SPS project, to be installed downstream QD519 in EYETS 2016-17. This ECR have been preceded by SRR SPS-BCTW-EC-0001 (EDMS: 1701629, approved at the 181st IEFC). The proposed vacuum chamber inner diameter (ID) is 76mm in contrary to the 80mm announced in the SSR.