The RF (Radio-frequency) system in the RAON (Rare isotope Accelerator complex for On-line experiment) is constructed as an HPRF systems supplying high RF power to the cavity, LLRF systems for controlling HPRF, and reference line system synchronizing every RF systems.
80 kW RF system for RFQ cavity have been designed to supply RF field in the RFQ cavity. In this paper, we will describe details of High power test for RFQ cavity and construct of the 80 kW SSPA.