MEDICIS Coordination - 26 July
Vincent - Giordano - Stefano - Simon - Elodie - Fabio - Laura - Joao - Julien - Moazam - Thierry
Feedback on 644M irradiation MD2 for 149Tb
irradiation overnight
proton beam focusing changed.
collection at A=149 , A=149+16=165 - 1hour each
La132 seen LaO 148Tb. , some 149Tb.
Ask 145Eu measurement on slit if mass miscalibatrion.
miscalibration : spectroscopy on one of slit.
Collection chamber : send proposition for improvement.
Ta644M: calibration of ion source. Laura will produce 647M with Re ion source.
check Tb efficiency.
2 collection reports to be made :
one on the last 169Er collection : Roberto Formento
one on the 149Tb MD2 collection this week : Julien
New planning logbook and planning available:
3 collections / shipments in August
2 collections/shipments in September
Results from Tyvek/ results from vial + tool pending
microscheduling;
Monday send target Ta644M to irradiation
cabling for cameras :start on Monday (1 day on Robot side)
+ access for Montrac switch by Giordanno
corridor on tuesday
Vincent : Lasers : tuesday am
impact is done ?
Julien will follow up
AOB:
Laura : follow up on Timber data logging
Stefano : prepare spec of antechamber + fumehood —> Ball and tongue can be installed: redo the box in plexi/alu
create a working place for MEDICIS mecatronics in Front end mounting room : Laura/Moazam
Target production : need to launch 2 units:
high density Ta, Re or W ?, no MM.
Julien Thiboud will produce, Joao follows-up
planning for remote handling for August needs to be cross checked as both Jean Louis and Giordanno will be away.