SRF R&D Seminar
Description
SRF R&D seminars are seen as a place to discuss subjects and ideas that are interesting, exciting and or novel. The seminars are informal and seen as a place for open discussion, and topics presented can range from first ideas, through work in progress, to presentation of final results.
Naturally, if you have ideas or suggestions for topics (either presented by yourself or by an invited speaker), please do not hesitate to contact the convenor.
Finally, for your convenience SRF R&D members have been added to an SRF R&D group (with associated email = SRF-RD@cern.ch)
SRF R&D Seminars: General
- There is a dedicated open e-group/mail list: SRF-RD@cern.ch
- Seminars are nominally every 2 weeks, with one or two topics per seminar.
- Indico area: https://indico.cern.ch/category/7357/
- Seminar Convenor: Alick Macpherson. Scientific Secretary: Anton Ivanov
SRF R&D Seminar: 5 March 2019:
- SRF R&D Directions and Priorities - Frank Gerigk
- Topics of RnD:
- FCC work packages
- WP3 (cavity performance & thin film development): Looking to focus on this package over the coming 1-2 years
- WP4 (Evaluate and understand the ultimate performance of Nb/ Cu technology): Mostly done => Action:Invite Sergio to present results
- WP5 (Fabrication of seamless cavities): (LNL collaboration: Renewed effort in 2019, looking for new ways to do seamless cavities.
- WP8 (Crab cavity challenges): Focus on prototype performance over next 2 years. Action: Invite Alexej to present status and upcoming objectives
- Other R&D projects
- Fast Reactive Tuner: Supported in 2019 and review in Q3 of 2019 to assess viability for next phase
- Flux trapping and thermo electric currents: ongoing investigating role of currents in cooldown and flux expulsion on bilk Niobium
- 2nd QPR: Expected to be operational this year.
- TES + Temperature mapping: needed for coated cavities
- High Gradient: Cryostat program is halted but target is to finish testing and tuning of bare cavities in 2019. Follow up on idea of using stainless steel helium tanks.
- Awaiting decision on possible PERLE collaboration
- FCC work packages
- Longer term view
- FCC: Look to investigate high performing 400MHz single cells cavities and an LHC compatible FCC cryomodule
- requires continued coatings development, and may need improved magnetic shielding and B-field control on vertical cryostat
- cryomodule performance limit may be due to the couplers => needs to be further investigated , but aim should be to reduce static heat load
- For high Q, look at possibility of coated 800MHz cavities with Each above 20MV/m
- Investigating possibility of modified insert for SM8 vertical cryostat that would allow for testing QPR in SM18. initial brainstorming started.
- FCC: Look to investigate high performing 400MHz single cells cavities and an LHC compatible FCC cryomodule
- Topics of RnD:
- TTC Highlights
- Frank
- CEBAF - without maintenance ~2% loss of acc gradient -> ~1 cryomodule per year
- SNS - plasma processing done in the tunnel directly -> ~25 % increase of the gradient - maybe useful for us
- XFEL - only 14.7 GeV achieved vs 17.5 GeV foreseen - optimisation of the power distribution scheme is presently used to increase the voltage
- FNAL - used HOM couplers to apply plasma treatment - lower power was needed
- DASY - trying to repeat nitrogen infusion with limited success
- Sam Posen - new world record Nb2Sn: 23 MV/m - nice result but not sure why
- Giovanna
- Temperature mapping: Use of pin diodes used for T-mapping and T -mapping in Cornell
- Main point of discussion: issues and details for cryomodule transportation
- Transport of crab cryomodules is planned from Vancouver to CERN, and so is a very relevant topic for us
- Katarzyna
- Fault analysis ( CEBAF = 500 /month vs CERN LHC = 40/year in CERN)
- Automated HPR (FRIB) but with only basic rinse quality control => CERN HPR quality control is more advanced and should be presented
- LLRF: development of system to address Lorentz Force detuning oscillations
- Walter
- N-infusion remains a mystery
- Questions about what FNAL results…. what are we seeing, as error bars a re absent., so difficult to assess if different cavity treatment variations are significant
- FNAL focusing on Q Disease by looking at the surface, Niobium Hydride formation, and hydride susceptibility as a function of repeated cool downs
- Frank
There are minutes attached to this event.
Show them.