Hardware (Stephane)
- In a good state
- Impedance and vacuum acceptance tests before long (tank)
- Optical line elements expected by March
- Installation foreseen this Summer (from June)
- Electronics detailed from tunnel to surface (BB5)
Software (Athanasios)
- First tests done on Proliant server (AWAKE)
- Not clear how to best handle image acquisition (free running until trigger or freeze)
- Need realistic test bench
- OP (Eric) asks for SISAcquisition property notified every basic period (system alive)
- Agreement that SBDS images will not be used to interlock injection of subsequent beams
Next steps:
- Stephane to equip VME crate with MEN-A25 CPU + XMC with digital camera and triggers
- Enrico to specify how to determine the best possible image (decaying as function of intensity)
There are minutes attached to this event.
Show them.