From: Torsten Koettig <torsten.koettig@cern.ch>
Sent: 04 August 2020 14:40
To: Luca Dassa <Luca.Dassa@cern.ch>
Cc: Laetitia Dufay-Chanat <laetitia.dufay-chanat@cern.ch>
Subject: RE: insert for impedance tests
Hi Luca,
Here is my draft calculation for the SV pipe diameter.
Please have a look and check with your calculations.
Pipe length is 50mm inside and 100 mm outside the vacuum vessel. All for the new pressure of 2.9 barg. 20 layers MLi on the phase separator and the flexible in the line at the cold part. 10 layer of MLI along that pipe.
I need to catch a tram at 12.15 from CERN to leave for vacation, so I need to go at least 11.45 around.
Yours Torsten