ERAM Meeting

→ Europe/Zurich
Alain Delbart (Université Paris-Saclay (FR))
    • 11:00 → 11:45
      ERAM status
      • 11:00
        ERAM production status at Rui's lab 5m
        Speakers: Alain Delbart (Université Paris-Saclay (FR)), Cyrille Vuillemin (Université Paris-Saclay (FR)), Laura Munteanu (CERN)
      • 11:05
        Mesh pulsing 10m
        Speakers: Cyrille Vuillemin (Université Paris-Saclay (FR)), Laura Munteanu (CERN), Laura-Iuliana Munteanu (CERN)

        No more pulse mesh last week

      • 11:15
        ERAM gluing 5m
        Speakers: Charlotte Riccio (Université Paris-Saclay (FR)), Cyrille Vuillemin (Université Paris-Saclay (FR))

         

         

        no more gluing last week

      • 11:20
        ERAM testing 10m
        Speakers: Charlotte Riccio (Université Paris-Saclay (FR)), Cyrille Vuillemin (Université Paris-Saclay (FR)), Laura Munteanu (CERN), Laura-Iuliana Munteanu (CERN)

        ----------------------------------
         

        After a trip during the high stats run this morning, the gain scans were started early.
        Gain scans with ERAM_13 were completed at 340V, 350V, 360V. Then, the setup was shut down and the gas flow was stopped.


        --------Metadata------------------
        Author: Katharina Lachner
        Status: open
        System Affected: Gas,Micromegas
        Message type: TPC
        TPC_Entry_Type: Operation
        ----------------------------------

      • 11:30
        ERAM AOB 15m
        Speakers: Alain Delbart (Université Paris-Saclay (FR)), Charlotte Riccio (Université Paris-Saclay (FR)), Cyrille Vuillemin (Université Paris-Saclay (FR))

        Stock of Stiffners/ FEC Cards / FEM Cards @ cern : => Stock-Stiffners-Available - Files - CERNBox: the CERN Cloud Storage

         

        Stiffner Statusi: #15 Stiffners (+2 not sanded)

         

        CAISSEStiffner #Comments
        A18cleaned @Ruis'Lab
         27cleaned @Ruis'Lab
         6cleaned @Ruis'Lab
         3cleaned @Ruis'Lab
         17cleaned @Ruis'Lab
        B42cleaned @Ruis'Lab
         41cleaned @Ruis'Lab
         44cleaned @Ruis'Lab
         43cleaned @Ruis'Lab
         46cleaned @Ruis'Lab
         45cleaned @Ruis'Lab
         47cleaned @Ruis'Lab
         48cleaned @Ruis'Lab
         5not sanded yet
         25not sanded yet
           
        TOTAL STIFFNERS @CERN15(2 not sanded yet)

        FEC Cards Status (#7 pairs of FEC cards)

         

        FEC#LEFT#RIGHTLocationComments
         5851box 1/2 
         7967box 1/2 
         8480box 1/2(fund into blue cabinet)
         29box 2/2 
         831box 2/2 
         107box 2/2 
         304box 2/2 
             
             
             
        TOTAL STIFFNERS @CERN7Pair(s) of new FEC Cards ready to be used:  

         

        FEM Cards Status: #7 cards

         

        FEM#Comments   
        FEMS01en stock armoire bleue 1821,00  
        FEMS18en stock armoire bleue 1821,00  
        FEMP04en stock armoire bleue 1821,00  
        FEMS03en stock armoire bleue 1821,00  
        FEMS34en stock armoire bleue 1821,00  
        FEMS32en stock armoire bleue 1821,00  
        FEMS37en stock armoire bleue 182   
        FEMS007en stock armoire bleue 1821,00  
        FEMS13en stock armoire bleue 182   
        FEMS28en stock armoire bleue 182   
              
              
            Stock Carte FEM = 7,00

         

        Rack de 6 bouteilles livré le 15.07.2022 - (il reste une bouteille pleine pour les tests XRay)

        premier lot de 6 fin juillet: commande OK, rack reçu

        second lot début août: commande OK, rack reçu

         

        Stock actuel au 19.09.2022:

        • 10 bouteilles pleines (individuelles)
        • Lot de 12 bouteilles supplémentaires (connectées ensemble) reçues la semaine dernière pour le banc de test 'Full scan'

         

        • Stock FEC Cards: from Lpnhe on the way, will be delivered at CERN at 182
        • Stock FEM Cards: #10

        - Camera 360: en cours d'installation (test de connexion au réseau cern à poursuivre): Fonctionne localement via un téléphone mobile, quelques difficultée pour le faire reconnaitre sur le réseau cern