Description
We report on a proton radiation damage experiment on P-Channel CCD
newly developed for an X-ray CCD camera onboard the Astro-H
satellite. The device has been exposed up to 10^9 protons/cm2 at 6.7
MeV. The charge transfer inefficiency (CTI) is measured as a function
of radiation dose. In comparison with the CTI actually measured in the
CCD camera onboard the Suzaku satellite for 6 years, we confirm that
the new type of P-Channel CCD is radiation tolerant enough for space
use. The temperature dependence of the CTI is also reported.