Strip readout MRPC for the TOF System of the MPD/NICA Experiment.

Not scheduled
15m
Beurs van Berlage

Beurs van Berlage

Poster Sensors: 1c) Gaseous Detectors

Speaker

Vadim Babkin (Joint Inst. for Nuclear Research (RU))

Description

Multigap resistive plate chambers have proven to be the best choice for time-of-flight systems of large experiments such as ALICE, STAR, PHENIX. In the MPD experiment aimed at the study of hot and dense baryonic matter it has been also decided to use MRPCs. To reduce the number of TOF system channels it is advisable to use readout from each end of a strip. Several different prototypes of detectors with different geometries and readout electronics have been tested. The tests of the MRPC prototypes at the Nuclotron deuteron beam demonstrate a time resolution of about 65 ps and an efficiency of 99.8%. This value meets the requirements of the MPD experiment.

Primary author

Vadim Babkin (Joint Inst. for Nuclear Research (RU))

Co-author

Viacheslav Golovatyuk (Joint Inst. for Nuclear Research (RU))