Help us make Indico better by taking this survey! Aidez-nous à améliorer Indico en répondant à ce sondage !

Recent Results on CLIC X-Band Prototype Accelerating Structures

2 Dec 2008, 14:20
20m
Cockcroft Institute

Cockcroft Institute

UK

Speaker

Steffen Doebert (CERN)

Description

The CLIC study is conducting an extensive testing program towards a prototype accelerating structure suitable for a liner collider. The requirements for CLIC are a loaded gradient of 100 MV/m for pulse duration of 240 ns with a trip rate below 3*10-7 per meter. These accelerating structures are designed, fabricated and tested in collaboration between KEK, SLAC and CERN. Recent results from these experiments will be reported including a low group velocity accelerating structure which reached a gradient in excess of 100 MV/m with an acceptable breakdown rate.

Presentation materials