CLIC Experimantal and Breakdown studies
Breakdown studies meeting 22.08.2017
Present: Walter Wuensch, Sergio Calatroni, Iaroslava Profatilova, Jan Paszkiewicz.
Remote connected by Vidyo: Anton Saressalo, Andreas Kyritsakis from University of Helsinki.
Yinon Ashkenazy from Hebrew University of Jerusalem.
Speakers: Jan Paszkiewicz, Anton Saressalo, Iaroslava Profatilova.
Link to indico page https://indico.cern.ch/event/660663/
Agenda
1. Jan presents the last results from Dark Current Measurements at XBox2. The raw signals from Xbox 2 were shown. Frequency spectrum of for different power levels and background were shown. The Fowler-Nordheim plots were shown and together with calculated field enhancement factors. The evolution of signal before and after BDs were shown.
2. Iaroslava shown overview of results from test with different Repetition Rate. During previous meeting was shown that with lower repetition rate the BDR is higher. After this, the question about real applied voltage appeared. The analysis of BD waveforms shown small difference in voltage (the signals taken with HV probe), i.e. with lower Repetition Rate the mean voltage higher that voltage asked from power supply (~20 V with 5220V). But the difference in BDR for 100 Hz and 200 Hz with the same mean of voltage are not explained. Further investigation are needed.
The results from BD waveforms analysis taken with different materials and Marx generators were shown. (005 SLAC SS CuAg and 006 Nb as materials were tested with Marx generator #1 and Marx generator #2). The common BD waveform is the same for any configuration (for both electrodes materials and for both Marx generator). The specific BD waveforms were mentioned, when discharge is abruptly stopped during pulse. The tests shown that the difference between Marx generator #1 and #2 doesn’t effect to this. From the part analyzed BD waveforms, the bigger number of specific waveforms were found for 005 SLAC SS CuAg electrodes and almost absent for 006 Nb electrodes.
3. Plan discussion for conditioning tests.
As the electrodes were changed at LESs at CERN and at University of Helsinki, the main parameters for tests were discussed. In both systems (at CERN and at Helsinki) Hard Cu electrodes are installed. At CERN the geometry for electrodes (the edge) were optimized using Vahur advice after modelling. The procedures for electrodes cleaning were discussed (Electrodes at CERN were cleaned with standard CERN procedures twice + passivation with chromic acid, electrodes at Helsinki were not cleaned). Yinon mentioned that the electrodes arrived from CERN required additional cleaning before analysis and shared their recipe for cleaning.
The main parameters for conditioning test were discussed and agreed.
Next breakdown meeting will be on Tuesday, September 5.