In particle therapy, image guidance is vital for planning and treating, especially for abdominal lesions, where the respiratory motion hinders treatment accuracy. In this study, fast acquired interleaved 2D CINE MR images were used to quantify the tumour (GTV) motion over several breathing cycles, to evaluate the clinical approach based on deriving an internal target volume (ITV) from a 4DCT.
Data from seven patients treated with pencil-beam scanning carbon-ion therapy for abdominal lesions at the National Centre of Oncological Hadron-therapy (CNAO, Italy) were considered. For moving targets, a combined approach with abdominal compression, rescanning and gating at end-exhale is employed. The MR scan was performed on the same day of 4DCT acquisition. For 4 patients, an additional MR was acquired approximately after 1 week. The 2D CINE MR (300 frames acquired in 1.13 min) images centered on the target, along with a deformable image registration algorithm were used to quantify tumour motion. Afterwards, two ITVs were defined considering: (1) all the respiratory phases (
CINE MRI captured images from 12-20 breathing cycles in contrast to 4 from 4DCT. The ITV normalized for the GTV had median(iqr) values of 0.15(0.19), 0.32(0.52) and 0.8(0.97) for
Spatial differences between