Gas systems project
GAS M&O meeting 02 March 2020
Present: Beatrice, Roberto, Patrick, Kacper, LPh, Michal, Mara, Gianluca, Sabino
Indico: https://indico.cern.ch/event/893669/
ALICE #2282
- MTR
- One MFC of humidifier is in error —> LPh to check
Reminder:
-
- Alarm in power supply: DC MCB trip —> Michal/Patrick to check
- exhaust pressure regulation does not work
- CPV
- after one week of flushing still lines closed —> flow increased
- Humidifier: leak test done (few leaks found). LPh to prepare electrical plan
- TPC
- Second pump fully connected. Verified and it is ok
Reminder
-
- In the purifier the small thermic box triggered (also last year it happened) —> Patrick/LPh to check
- TRD
Reminder
-
- Recuperation: missing two valves but there are present in the software
- Purifier: to review if keep the safety valve or the rupture disk
- Purifier: safety valve at the input where we have Ar or Ar/H2 at high pressure —> LPh to check with safety
ATLAS #2283
- MDT
- Overshoot of 30 mbar of pressure when the gas system re-started —> to do a test next week (Kacper, Beatrice, Gianluca, Michal, Roberto). Kacper to summarise test already done
- Reminder:
- Found a problem of grounding on pressure sensors: pressure sensors changed. Now to verify if the grounding problem is still there
- Tried to changed from one pipe to the other. Try again to check all pressure.
- RPC
- Rack 63 stopped and rack 61 started
- Humidifier was moving a lot: Kacper adjusted the PID
- TGC
- Safety visit for welding in liquifier: to flush with CO2 and to prepare a list of what we want to do —> Kacper
Reminder
-
- Power of bande chauffant —> Patrick/Kacper
- Several electrical problem in ATLAS:
- See elog 2205, 2206, 2207
- Patrick to prepare a protocol for the student to identify the failures
CMS #no elog
- RPC
- Michal changed the mother board: now flow is 170 l/h (elog #2279) —> Andrea to check with new voegtlin red
- Reminder:
- Missing quick manifold and flowcell in barrel +1 and +2
- Swap of pipes in rack RE-1 (racks 61 and 65) and RPC 3.1 (racks 63 and 87)
- Rack 85: to check if dummy chamber is installed, if yes to add pressure sensor connection
- DT
- Change one motherboard in rack 61 but flow didn’t change (elog #2280) —> to try to recalibrate one set of flowcells
Reminder:
-
- Difficult to re-start the gas system after power-cut —> to do some tests
- Test for power cut and re-start for the exhaust line —> to do other tests
- GEM
- Very strange noise of the pump: Kacper dismounted and he found a lot of dust in electrical part and membrane damaged. Kacper to send the pump for checking and repairing
- CSC
Reminder:
-
- Warning to set-up —> Beatrice/Michal/Roberto
- CF4 Recovery
- To use battery A to finish and then exchange it with new battery (the one with single bottles)
LHCb #2281
- RICH1
- In closed loop with CO2. Stop during week-end
- to check if we take air —> Mara
- RICH2
- in closed loop
Reminder
-
- to inject Air —> Patrick to check with C. Frei
- to add line for analysis “supply to detector”
- MWPC
- Leaks in Purifier: it was absorbing the CO2 and for this reason we saw a big leak. Still a leak present
- Patrick to ask for some days off to search and fix the leaks
Reminder
-
- Leak in Mixer and Exhaust. Only in Exhaust found but not repaired. Other not yet founded —> Patrick to check when we can stop the system
- Interlock of Ar/H2 does not work —> Michal/Patrick to check
- Problem with Profibus cable/connector module —> to understand where —> Patrick
PIQUET
- ALICE CO2 supply: David’s team forgot to do the reset of the button for the supply
GENERAL
- Discussion on planning MFC: important to give the MFC on Monday to Fabio and Federico
- Patrick presented the activities of LHCb in 2019
- Mara to add: data of RICH1 for Air intake
- Mara to add: RICH2 recuperation
- Kacper show how to restart the ATLAS MDT gas system
- Discussion about pressure sensors drift: how many do we have?
- Michal and Roberto proposed if the system stop, software check the difference in pressure and it close the input and output valve of the leaking chambers —> Beatrice to check
- Michal proposed to create a document in EDMS for having the procedure for each gas system
- Sabino presented different types of flowmeters based on different technologies
- Suggestion: pressure in the loop to regulate with a pressure regulator to have it stable —> to think about
There are minutes attached to this event.
Show them.