9–13 Jul 2023
Hawaii Convention Center
US/Hawaii timezone

C3Or3A-01: [Invited] Loss of insulation vacuum tests on an EuXFEL-like cryomodule

12 Jul 2023, 14:00
20m
314

314

Speaker

Aman Kumar Dhillon (Deutsches Elektronen-Synchrotron DESY)

Description

Many Free Electron Lasers (FEL) are nowadays based on linear superconducting accelerators (linacs). The typical layout of such a linac consists of a number of cryomodules (CMs) arranged in strings. Each cryogenic circuit in a string is protected by safety valves (SVs) in case of failure of the system or a catastrophic event. A typical worst-case scenario considers the venting of the insulation vacuum, causing a fast and uncontrolled warm up of the cryogenic circuits. Such venting can for example take place across a pump port belonging to a string. The amount of heat deposited on each circuit is a very important parameter to correctly size the safety devices.
This paper describes the tests performed at DESY on an EuXFEL cryomodule to evaluate the heat input to the three cryogenic circuits of the CM while venting the insulation vacuum. Test results are given with a particular focus of their application to long strings.

Authors

Mrs Serena Barbanotti (Deutsches Elektronen-Synchrotron DESY) Mr Torsten Boeckmann (Deutsches Elektronen-Synchrotron DESY) Mr Yury Bozhko (Deutsches Elektronen-Synchrotron DESY) Mr Kay Jensch (Deutsches Elektronen-Synchrotron DESY) Mr Ronald Klos (Deutsches Elektronen-Synchrotron DESY) Mr Rajinikumar Ramalingam (Deutsches Elektronen-Synchrotron DESY) Dr Tobias Schnautz (Deutsches Elektronen-Synchrotron DESY) Mr Detlef Sellmann (Deutsches Elektronen-Synchrotron DESY)

Presentation materials