The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab was upgraded to 12 GeV in 2014, necessitating the use of high-power klystrons. The C75 and C100 cryomodules, which enable the 12 GeV operation, are capable of achieving higher gradients and are powered by 8 kW and 13 kW klystrons, respectively. Over the past decade of operating at 12 GeV, we have observed a decline in power output due to issues with power supplies, mistuned cavities, and other hardware failures. At Jefferson Lab, klystron tubes can be diagnosed on a test stand designed for 8 kW and 13 kW tubes. We will present test stand results for selected tubes that exhibited lower than expected output power, including an attempt to retune a tube.