Speakers
Prof.
Mara Bruzzi
(Universita e INFN (IT))
Mara Bruzzi
(Dipartimento di Fisica)
Description
R. Mori, M. Bruzzi, Z. Li, M. Scaringella INFN and University of Florence, Italy BNL, Upton New York
n-type MCZ Si detectors have been irradiated with different particles and fluences: (a) fast neutron up to 1.5x10^14n/cm^2; (b) fast neutrons (1.5x10^14n/cm^2) and 60Co gammas (500MRad); (c) fast neutron (3x10^14n/cm^2) and 60Co gammas (500MRad), in view to test a possible radiation hardening effect due to gamma irradiation occurring on neutron irradiated detectors.
In this work we examined the possible introduction of shallow donors
in these detectors with the TSC technique performed in the low
temperature range (5-80K). Preliminary results of this experimental study are shown and discussed.