apologies: F. Duarte Ramos, W. Klempt, L. Linssen
direct link to webex
Present at the meeting;
B. Cure, K. Elsener, A. Gaddi, L. Gatignon, H. Gerwig, A. Sailer

Summary Notes:
Konrad gave a short introduction to the meeting, reminding everyone of the post-CDR work on a CLIC detector concept and of the - temporarily? - much reduced list of "a priori" assumptions.

The main topic of the meeting was the possible reduction of iron in the CLIC_SiD yoke, work done primarily by B. Cure. A shorter version of his presention will be shown at the CLICdp meeting (detector optimisation session) on 10 June.

The main conclusion are that:
-> reducing the half length of CLIC_SiD from 6.2 m to 5 m is feasible
-> in terms of magnetic field homogeneity and stray field, the iron remove from the endcap yoke can be replaced to a good approximation by a set of "end-coils"
-> the design parameters of these "end-coils" are realistic, when compared to the LHCb dipole magnet coils

In an exploratory study, Benoit found that the iron in the endcap yoke could be reduced further, but the end-coils would then have to become superconducting ones. The iron in the barrel yoke can be reduced by a substantial amount without any compensatory measures, the strayfield increases only by a rather small amount in this case.

In the discussion, Andrea Gaddi stressed that for future detector optimisation discussions one should consider models without 90degree corners in the path of the cables/services. To be studied by looking e.g. at CMS.

AFTER THE MEETING: Konrad added the slides from a talk by Suzanne van Dam (CERN techn. student) who investigated different types of materials in the support tube of the LumiCal/BeamCal. The study was done for CLIC_ILD, and the aim was to improve the shielding of the HCAL endcap against secondaries from the high rate of incoherent pairs hitting mostly the region around the BeamCal.




There are minutes attached to this event. Show them.
    • 16:00 16:10
      Introduction 10m
      Speaker: Konrad Elsener (CERN)
      Slides
    • 16:10 16:30
      Reducing Iron in the Endcap Yoke of CLIC_SiD 20m
      Speaker: Benoit Cure (CERN)
      Slides
    • 16:30 16:40
      Status of CLIC detector optimisation 10m
      link to Det Optim. Indico pages
      very early draft layout drawings for discussion
    • 16:40 16:50
      AOB. and next meeting 10m
    • 16:50 16:55
      For Information: Occupancy from incoherent pairs 5m
      Study of the occupancy from incoherent pairs in the HCAL endcap; includes material choices for the support tube, etc. Talk given at the FCAL workshop in Bucharest, 26 May 2014