Speaker
Dr
Stephen Biagi
(University of Liverpool)
Description
The charge collection properties of the LHCb n on n silicon
Strip detector was modelled using the DIOS and DESSIS
Packages from the ISE/synopsys program suite.
The detector response to MIPS was modelled in detail as a function
Of applied bias voltage,radiation damage and incident track angle.
a centroid shift in the collected charge between positive and
Negative incident track angles has been predicted and operational
Bias voltages deduced.
Primary author
Dr
Stephen Biagi
(University of Liverpool)