Speaker
Dr
Yonghwan Kim
(Institute for Basic Science)
Description
RAON fully superconducting ECRIS which plasma chamber volume of 10 liters is adapted and uses a 28 GHz MW power as a main power source and an 18 GHz MW power as a secondary power source. We characterized our ion source at a relatively low magnetic field just with an 18 GHz MW power. A reference O$^{7+}$ beam was monitored with the experimental parameters such as MW power, vacuum pressure, and magnetic field profile. Under some conditions, the beam current showed unstable behavior due to a plasma instability. We verified the reason of that instability and verify the characteristics of our ECRIS.
Authors
Dr
Yonghwan Kim
(Institute for Basic Science)
Mr
Jeongil Heo
(Institute for Basic Science)
Dr
Ishiyama Hironobu
(Institute for Basic Science)