18/04/2018, 08:45
-
Dirk Lipka (DESY)18/04/2018, 09:00Talk
All electron beamlines of the EU-XFEL were supplied this year. The electron diagnostics supported the commissioning of the last beamline. In this contribution new results of the diagnostics will be shown. In addition recent problems will be discussed.
Go to contribution page -
Dr Michael Abbott (Diamond Light Source)18/04/2018, 09:25
At Diamond we have been developing the control system for our multi-bunch feedback system for more than a decade, adding increasingly more functionality. Until recently the digital signal processing was limited by our use of the ageing Libera TMBF platform, but starting in 2016 we have been migrating to a platform based on MicroTCA and commercial off the shelf hardware.
The new hardware...
Go to contribution page -
Edmund Blomley (Karlsruhe Institute of Technology (KIT))18/04/2018, 09:50Talk
The Karlsruhe Research Accelerator (KARA) as a test facility provides an excellent environment for the development and benchmarking of new diagnostics. Examples of recent developments are the ultra-wideband readout electronics for ps-fast detectors, KAPTURE, and an ultra-fast line-camera with up to 10 Megaframes per second and continuous data streaming for optical and electro-optical bunch...
Go to contribution page -
Laura Torino (ESRF)18/04/2018, 10:15Talk
The ESRF-EBS new BLDs are commissioned and operational and an application to visualize the whole situation of the losses around the storage ring has been developed. Slow data are stored during normal operation at 1 Hz in order to correlate the losses with events happening around the machines such as vacuum problems or insertion devices motion. Fast average data are stored during the injection...
Go to contribution page -
Mrs Niki Vitoratou (Diamond Light Source and Royal Holloway University)18/04/2018, 11:00Talk
We are investigating a range of approaches to make Resonant Spin Depolarisaton (RSD) compatible with user beam operation at DLS. To improve the reliability of loss measurements, we depolarise only one half of the bunch train, and use the loss rate in the other half to normalise. We use specifically designed array of four scinitillators placed around the beam pipe after the collimators to...
Go to contribution page -
Nicolas HUBERT (Synchrotron Soleil)18/04/2018, 11:30Talk
Soleil is currently working of two new monitors:
- Dose monitors based on RadFET sensors: preliminary tests and developement of dedicated readout electronics will be presented.
- Loss Monitors: preliminary tests with scintillators or cerenkov radiator and calibration results will be presented.
-
Dr Alun Morgan (Diamond Light Source)18/04/2018, 12:00Talk
In order to improve coverage of beam loss measurements, we have been investigating the use of a fibre based time of flight measurement.
Go to contribution page
A prototype system has been installed, with fibres installed across cells one and two, starting just downstream of the injection kicker magnets. The fibres are positioned in the beam plane horizontally, one fibre in board and one out board. Sensors are... -
Volker Schlott (Paul Scherrer Institut)18/04/2018, 13:30Talk
SLS 2.0 is the upgrade project of the Swiss Light Source (SLS) at the Paul Scherrer Institut in Villigen, Switzerland. It aims to reduce the natural emittance by a factor of ~ 40 by replacing the triple bend achromat with a 7-bend achromat structure. The issues of stability and reproducibility of this higher brightness and more coherent photon beam was recently addressed in an internal photon...
Go to contribution page -
Benoît Roche (ESRF)18/04/2018, 14:00Talk
In order to check the quality of the BPM blocks that will be installed in the ESRF-EBS we have developed a RF characterization bench, which simply measures the transmission between each of the 4 buttons. Every BPM block is measured at least twice: first when they arrive from the manufacturer, and later after being assembled on a girder, with 2 out of 10 of these BPMs also having undergone NEG...
Go to contribution page -
Dr Friederike Ewald18/04/2018, 14:30Talk
The 1500 BPM-buttons for ESRF-EBS had suffered from un-expected UHV leakage problems that are now clearly identified as bulk defects in the steel used for BPM body. These defects were identified with the help of X-ray computed tomography (CT) performed at two ESRF beamlines dedicated to this technique. The CT scans allowed to correlate the existence of small (<10um) but long (>10mm) channels...
Go to contribution page -
Dr Gabriele Brajnik (Elettra - Sincrotrone Trieste), Raffaele De Monte (Elettra - Sincrotrone Trieste)18/04/2018, 15:30Talk
A new-concept BPM was developed to prove the usefulness of pilot tone technique in channels equalization, thermal drift compensation and self-calibration.
Go to contribution page
It ran successfully not only during various machine shifts, but also during a user dedicated beamtime shift for more than 10 hours, behaving in a transparent way for all the control systems and users. The equivalent RMS noise (10 kHz data... -
Mr David Yepez (CELLS-ALBA)18/04/2018, 15:55Talk
Due to recent unknown noise problems in ALBA beam position, a new python application has been developed in order to catch and track particular frequency components along the runs. Such application takes the BPMs 10kHz data from the Fast Archiver at a given periodicity, analyzes the BPMs spectrum and stores the tracked components into a log file for later off-line analysis. We will present how...
Go to contribution page -
Marie Labat (Synchrotron SOLEIL)18/04/2018, 16:15Talk
In one of the long straight sections of SOLEIL is installed a pair of canted undulators for the ANATOMIX and NANOSCOPIUM beamlines. Since the upstream undulator radiation can potentially damage the downstram undulator magnets, an accurate survey of the respective alignement of the two devices is mandatory. An XBPM was initially installed for this purpose. But for redundance and further...
Go to contribution page -
Chris Bloomer (Diamond Light Source Ltd.)18/04/2018, 16:40Talk
Beamline detectors operating in the 100-1000Hz regime are becoming more common, and the X-ray beam stability demanded by beamlines is also thus of comparable bandwidths. In order to maintain the positional stability of a focussed X-ray beam at the beamline sample-point at bandwidths of up to ~500Hz, it is proposed to introduce a feedback system that makes adjustments to the X-ray source point...
Go to contribution page -
18/04/2018, 17:00
-
Manuel Cargnelutti (Instrumentation Technologies)19/04/2018, 08:30Talk
One of the frontiers that novel beam diagnostics and readout electronics will explore in the future is bunch-by-bunch information. Both for the electron synchrotrons and for the high repetition rate LINACs, bunch-by-bunch beam information will be useful to better understand and control the machine. As a first step to explore this field, I-Tech prototyped a 500MSps digitizer which features 4...
Go to contribution page -
Hussein Al-Mohammad (SESAME)19/04/2018, 09:00Talk
SESAME is a 2.5 GeV 3rd generation Synchrotron Light Source in Allan, Jordan. The commissioning of the Storage Ring has been done in spring 2017. The storage ring is equipped with 64 BPMs ,3 fluorescent screens, FCT, DCCT, 4 BLMs, 2 Bunch by Bunch kickers and one Synchrotron Radiation Monitor. This talk gives an overview of the Diagnostics elements and our experience during the commissioning....
Go to contribution page -
Lorraine Bobb (Diamond Light Source)19/04/2018, 09:30Talk
Fourth generation light sources operate with low emittance to provide more brilliant beams for user experiments. These machines have set the bar for non-invasive transverse beam size measurement on the micron and sub-micron scales. It has been identified within the community that this spatial resolution is at the limit of most diagnostic instrumentation, and systems which more closely resemble...
Go to contribution page -
Ji-Gwang Hwang (Helmholtz-Zentrum Berlin)19/04/2018, 10:30Talk
Beam halo induced by space charge force and scattering of trapped ions is one of the critical issues for linac based high power machines such as bERLinPro. In order to suppress uncontrolled beam losses, the coronagraph based halo monitor was designed and optimized to measure the beam halo which has ∼ 10^−4 contrast to the beam core. The beam test was performed in BESSY-II. In this...
Go to contribution page -
Laura Torino (ESRF)19/04/2018, 11:00Talk
The momentum compaction factor of a storage ring can be obtained by measuring how the beam energy changes with the RF frequency. Direct measurement of the beam energy can be difficult, long or even not possible in some machines such as ESRF. Since the energy spectrum of the synchrotron radiation depends on the beam energy, it is indeed possible to relate the variation of the beam energy with a...
Go to contribution page -
19/04/2018, 11:30
-
19/04/2018, 11:45Talk
Choose timezone