On a new environment-friendly gas mixture for Resistive Plate Chambers

28 Sept 2022, 09:25
25m
500/1-001 - Main Auditorium (CERN)

500/1-001 - Main Auditorium

CERN

400
Show room on map

Speaker

Giorgia Proto (INFN e Universita Roma Tor Vergata (IT))

Description

The standard gas mixture for the Resistive Plate Chambers (RPC), composed of $\rm{C_{2}H_{2}F_{4}}$/i-$\rm{C_{4}H_{10}/SF_{6}}$, allows the detector operation in avalanche mode, as required by the high-luminosity collider experiments. The gas density, the low total charge delivered inside the gas and the comfortable avalanche-streamer separation guarantee high detection efficiency, rate capability and slow detector ageing.
The standard RPC gas mixture is mostly based on Hydrofluorocarbons, HFCs, extensively used in the refrigeration industry. The Hydrofluorocarbons are now considered to be non-eco-friendly gases for their high Global Warming Potential (GWP). The $\rm{SF_{6}}$ has the largest GWP, 22900, but, due to its low concentration, it contributes only with few tens of units to the total value. The major contribution comes from the main standard gas mixture component, the $\rm{C_{2}H_{2}F_{4}}$ (GWP $\sim$ 1300). This gases are not recommended for industrial uses anymore, thus their availability will be increasingly difficult over time and the search for an alternative gas mixture with low-GWP is then of absolute priority within the RPC community.
In this presentation we report the performance of the RPC working with new environment-friendly gases with low GWP which could replace the standard mixture. In this work the standard mixture main component, the $\rm{C_{2}H_{2}F_{4}}$, is replaced by a proper mixture of $\rm{CO_{2}}$ (GWP = 1) and Tetrafluoropropene ($\rm{C_{3}H_{2}F_{4}}$, GWP$\sim$6). The other high-GWP component, the $\rm{SF_{6}}$, is replaced by a new molecule, the Chloro-Trifluoropropene ($\rm{C_{3}H_{2}ClF_{3}}$, GWP $\sim$ 5) never tested in the RPC detectors. The mixtures studied have a total GWP $\sim$ 10.
We report, for several eco-gas mixtures, the detection efficiency, streamer probability, electronic and ionic charge as a function of the high voltage. Moreover the timing properties are studied and the detector time resolution is measured.
We also focus the attention on a new category of signals having intermediate properties between avalanche and streamer, called "transition events". This category is negligible for the standard gas mixture but relevant for HFO/$\rm{CO_{2}}$-based gas mixtures.
We show a direct comparison between $\rm{SF_{6}}$ and $\rm{C_{3}H_{2}ClF_{3}}$ to study in depth the possibility to replace an industrially very important molecule like $\rm{SF_{6}}$.

Primary authors

Giorgia Proto (INFN e Universita Roma Tor Vergata (IT)) Dr Liberti Barbara (INFN) Prof. Rinaldo Santonico (INFN e Universita Roma Tor Vergata (IT))

Co-authors

Dr Giulio Aielli (INFN e Universita Roma Tor Vergata (IT)) Prof. Paolo Camarri (Università degli Studi di Roma Tor Vergata) Prof. Roberto Cardarelli (INFN) Prof. Anna Di Ciaccio (INFN e Universita Roma Tor Vergata (IT)) Mr Luigi Di Stante (Università degli Studi di Roma Tor Vergata) Dr Alessandro Paoloni (Laboratori Nazionali di Frascati (LNF)) Dr Enrico Pastori (INFN) Dr Luca Pizzimento (INFN) Dr Alessandro Rocchi (INFN)