Help us make Indico better by taking this survey! Aidez-nous à améliorer Indico en répondant à ce sondage !

27 August 2017 to 1 September 2017
RAI Congress Center, Amsterdam, The Netherlands
Europe/Amsterdam timezone

Design considerations of gantry beamline with fast energy modulation for HUST Proton Therapy Facility

30 Aug 2017, 13:15
1h 45m
Posters Area

Posters Area

Poster Presentation of 1h45m D3 - Magnets for Other Medical and Biological Applications Wed-Af-Po3.04

Speaker

Dr Bin Qin (Huazhong University of Science and Technology)

Description

HUST proton therapy facility is a Major State Research & Development Program supported by MOST, China. This facility is based on an isochronous superconducting cyclotron with two gantry beam lines and one fixed beam line. This paper will discuss the beam optics and main magnetic elements including dipoles, quadrupoles and fast scanning magnets of the gantry beam line. As well as the Energy Selection System (ESS) will be introduced with key features which enable fast energy modulation of proton beam between 70 MeV to 240 MeV.

Submitters Country China

Primary authors

Dr Bin Qin (Huazhong University of Science and Technology) Dr Kaifeng Liu (Huazhong University of Science and Technology) Dr Jun Yang (Huazhong University of Science and Technology) Mr Wei Chen (Huazhong University of Science and Technology) Mr Xu Liu (Huazhong University of Science and Technology) Mr Zhikai Liang (Huazhong University of Science and Technology) Mr Qushan Chen (Huazhong University of Science and Technology) Dr Ping Tan (Huazhong University of Science and Technology) Prof. Kuanjun Fan (Huazhong University of Science and Technology)

Presentation materials