Help us make Indico better by taking this survey! Aidez-nous à améliorer Indico en répondant à ce sondage !

27 August 2017 to 1 September 2017
RAI Congress Center, Amsterdam, The Netherlands
Europe/Amsterdam timezone

A method based rotating coil to find magnetic center for series quadrupole magnets at IMP

31 Aug 2017, 13:45
1h 45m
Posters Area

Posters Area

Poster Presentation of 1h45m G5 - Magnetization and Field Quality Thu-Af-Po4.10

Speaker

Dr Wenjie Yang (colleague)

Description

For the quadrupole magnets of the Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU), the location of the magnetic center has to be known. The FRIB included 115 quadrupole magnets in seven kinds of specifications, to minimize the measurement time and cut the measurement costs, the IMP Magnetic and Machinery Department proposed a method using a rotating coil to measure the magnetic center of the quadrupole magnets with different diameter. The measurement procedure is described and the reproducibility is achieved. In addition, the measurement results of the quadrupole magnets with different diameter are illustrated.

Submitters Country China

Primary author

Jing Yang (Institute of Modern Physics Chinese Acdemy of Sciences)

Co-authors

Dr Wenjie Yang (colleague) Mr Qinggao Yao (colleague) Dr Guozhu Cai (colleague)

Presentation materials

There are no materials yet.