Design of dipole magnet integral measurement system for HTPTF

31 Aug 2017, 13:45
1h 45m
Posters Area

Posters Area

Poster Presentation of 1h45m G8 - Novel Diagnostics and Other Techniques Thu-Af-Po4.11

Speaker

Dr Jun Yang (Huazhong University of Science and Technology)

Description

A new proton therapy facility (HTPTF) is under construction in Wuhan, China. The dipole magnet integral measurement system was designed for the beam transport system of the HTPTF. The design goal is to build a reliable, precise, automatic measurement system, and it is accurate enough to characterize the magnetic field quality of the dipole magnets in the beam transport system. The integral measurement system consists of a long coil, precision motion stages, data acquisition and control system. The design of the whole system and the measurement method is described in this paper. The design and fabrication of the long coil are also discussed, and the errors from the geometric frame of coil and electronic equipment are analyzed.

Submitters Country China

Primary author

Dr Jun Yang (Huazhong University of Science and Technology)

Co-authors

Mr Hui Liang (Huazhong University of Science and Technology) Mr Wei Chen (Huazhong University of Science and Technology) Prof. Bin Qin (Huazhong University of Science and Technology)

Presentation materials