A high precision superconducting levitation system for gravity measurement has been developed which used the levitation of a superconducting sphere by the magnetic field of two superconducting coils. The magnetic levitation is designed to provide independent adjustment of the levitating force and the force gradient. A GM cryocooler is employed to cooldown the system. This article reviews the construction and operating characteristics of the system. The test results show that the system is allowed at least 10-10g sensitivity.

Submitters Country China

Primary authors

Dr Xinning Hu (1Institute of Electrical Engineering, Chinese Academy of Sciences) Qiuliang Wang Dr Hui Wang (1Institute of Electrical Engineering, Chinese Academy of Sciences) Dr Chunyan Cui (1Institute of Electrical Engineering, Chinese Academy of Sciences) Prof. Yinming Dai (1Institute of Electrical Engineering, Chinese Academy of Sciences) Dr Yi Li (1Institute of Electrical Engineering, Chinese Academy of Sciences)