Help us make Indico better by taking this survey! Aidez-nous à améliorer Indico en répondant à ce sondage !

27 August 2017 to 1 September 2017
RAI Congress Center, Amsterdam, The Netherlands
Europe/Amsterdam timezone

AC Loss Properties of Stacked Multifilamentary REBCO Superconducting Tapes

30 Aug 2017, 13:15
1h 45m
Posters Area

Posters Area

Poster Presentation of 1h45m G4 - Losses in Conductors and Coils Wed-Af-Po3.12

Speaker

Mr Tetsuya Ito (Kyushu University)

Description

For ac applications of superconductors, ac loss is most of the heat load. So it is very important to estimate the ac losses in superconducting windings for the design of cooling system. However the measurement of ac loss takes much time and cost and also needs large facilities. So simple and easy estimation method of ac loss is required. In this study we investigated the ac loss properties of multi-filamentary REBCO superconducting tapes which were made by the IBAD-PLD technique and laser-scribing. The thickness of a REBCO superconducting layer was 3.6μm. The length and width of sample tapes was 60mm and 10mm respectively. We measured ac losses of sample tapes with a saddle-shaped pick-up coil applying ac magnetic field perpendicularly to the tape face. Temperature was 30, 40, 50, 64 and 77 K. Number of stacked tapes was 1, 3 and 6. We measured the ac losses in multi-filamentary REBCO superconducting tapes and compered with the ac loss of non-scribed tapes. The number of filament of the laser-scribed tape was 4. When the observed ac losses were normalized by Ic0, which was the evaluated critical current at zero field at the respective temperature by using the observed magnetization curve, those agreed with one master-curve regardless of temperature. The ac losses were scaled with temperature whether the tapes were scribed or non-scribed. In addition the ac losses were scaled regardless of the number of stacked tapes. However the dependences of ac losses on the number of stacked tapes for the smaller amplitude than the penetration field, Bp, were different between the scribed tapes and non-scribed ones. In this conference, we will report the observed results and discuss on the simple and easy estimation methods of ac losses.

Submitters Country Japan

Primary author

Mr Tetsuya Ito (Kyushu University)

Co-authors

Masataka Iwakuma (Kyushu University) Akira Tomioka (Fuji Electric) Masayuki Konno (Fuji Electric) Teruo Izumi (Advanced Industrial Science and Technology) Kazuhisa Adachi (SWCC Showa Holdings Co., Ltd.) Takato Machi (Advanced Industrial Science and Technology) Akira IBI (Advanced Industrial Science and Technology)

Presentation materials