Conveners
Session 1; 10-nov 2017;
- Krystian Roslon (Warsaw University of Technology (PL))
-
Mr Paweł Jagoda (AGH UST, JINR ), Mr Mariusz Wtulich (Gdańsk University of Technology, JINR)10/11/2017, 09:00NICA acceleration and experimental complexTalk
Process involving bombarding a surface with dashing abrasive particles called sandblasting is often used in industry to clean surfaces of different objects by removing paints, impurities or corrosion products. It is the basic tool to remove oxides after heating of alloys being the future implant in prosthetics. Another important area of its application is an induction of nanocrystallization...
Go to contribution page -
Piotr Kopaczewski, Gabriela Pokropska10/11/2017, 09:10Student program: TeFeNica, Team for the Future of NICA Dubna 2017Talk
Comparision results from THESEUS model with Na49 experiment for transverse mass, rapidity spectra and also comparision HBT from NicaFemto and MpdFemto.
Go to contribution page -
Mr Krystian Roslon (Warsaw University of Technology (PL))10/11/2017, 09:20Student Program: SCS-2017 Slow Control System Dubna 2017Talk
The MPD (Multi Purpose Detector At NICA) experiment which is under construction at Laboratory of High Energy Physics at Joint Institute for Nuclear Research will be studying relativistic heavy ion collisions. Such experiments produce not only experimental data but also variety of operational parameters which should be monitored and controlled during regular functioning. For this purpose Slow...
Go to contribution page -
Barbara Kędzierska (Warsaw University of Technology), Tomasz Kowalski10/11/2017, 09:30Student Program: SCS-2017 Slow Control System Dubna 2017Talk
It is very important to properly supply the electronic circuits; therefore, in the Polish Group of Experts at ZIBJ in Dubna, we devote major attention to the whole project of the Slow Control System. The sophisticated measurement system of the MPD-NICA experiment generates a lot of electrical impulses that interfere with sensitive electronics and may disrupt proper operation of the system....
Go to contribution page -
Tomasz Zalewski (Warsaw University of Technology), Klaudia Zardzewiala (Politechnika Warszawska), Aleksandra Fliszkiewicz (Warsaw University of Technology)10/11/2017, 09:40Student Program: SCS-2017 Slow Control System Dubna 2017Talk
Power supply is obviously essential for all electrical appliances. However, for advanced and sophisticated network that require enormous number of connections and supply different types of devices this problem becomes crucial. According to the idea of slow control such system should be designed in the way to ensure scalability, flexibility, reliability and remote controlling with all typical...
Go to contribution page -
Patryk Okoński10/11/2017, 10:00Student program: TeFeNica, Team for the Future of NICA Dubna 2017Talk
Electric power distribution system comes with a set of features that allow user to control RACK's power supply. It consists of several work modes:
- AUTO mode
- MANUAL mode
- PHASE ANALYER mode
- CALIBRATION mode
Each mode can be accesed invidually from Main Control Panel. "Auto mode" provides automatic phases load balancer while "Manual mode" allow user to manually switch phases that...
Go to contribution page -
Mr Aleksander Kubań, Ms Aleksandra Bedełek (Politechnika Warszawska)10/11/2017, 10:10Student Program: SCS-2017 Slow Control System Dubna 2017Talk
The goal of our work was to build the electronic combination lock by using equipment from roger company. The elements that we used were following:
Go to contribution page
- Network Controller,
- Communication Interface,
- Access Controller,
- Electronic Lock,
- Metal Enclosure with Transformer.
The course of action:
We read the manual and connected all the elements as shown in instructions(manual).
Next we tested it... -
Radosław Gryta10/11/2017, 10:20Student Program: SCS-2017 Slow Control System Dubna 2017Talk
High voltage power supply uses modbus protocol in order to receive commands. I had to create control program with LabVIEW software that would allow to change values of specific registers and check values that are already there. RACKs' cooling system is combination of temperature sensors and electromechanical relays. We use RS-485 in order to communicate through modbus protocol with temperature...
Go to contribution page -
Agnieszka Domalewska (Gdańsk University of Technology), Szymon Rowiński (Politechnika Warszawska), Radosław Krzosa (Warsaw University of Technology)10/11/2017, 10:30Student Program: SCS-2017 Slow Control System Dubna 2017Talk
Main goal of the work in Dubna was creating an extinguishing system to detect danger and initiate action in such case in the RACK cabinets. In the received extinguishing module, configuration of the software had to be performed using Slow Control System standards.
Go to contribution page
Firstly, the performance parameters of the extinguishing modules had to be evaluated. The properties such as the physico-chemical... -
Adrian Krężel (Warsaw University of Technology)10/11/2017, 10:40Student program: TeFeNica, Team for the Future of NICA Dubna 2017Talk
Presentation include informations about RACK’s hardware that allow safety three-phase circuit power supplying. There will be also informations about programming National Instruments 9403 and 9475 modules, that could be helpful in developing intelligent power supplying system in future. This presentation is focused on building RACKS’s power supplying hardware, less on software.
Go to contribution page -
Ashima Vashistha, Filip Protoklitow, Jan Wójcik10/11/2017, 10:50Student Program: SCS-2017 Slow Control System Dubna 2017Talk
Slow Control Systems (SCS) are electronic systems that are used to
Go to contribution page
setup, monitor and enable operation of complex hardware for physical experiments.
Detectors MPD (Multi-Purpose Detector) and BM@N (Baryonic
Matter at Nuclotron) at NICA (Nuclotron-based Ion Collider fAcility)
complex are some implementations of this system. For the purpose of this
machinery it will be necessary to... -
Przemysław Wilczyński10/11/2017, 11:00Student program: TeFeNica, Team for the Future of NICA Dubna 2017Talk
Slow controls system consists of number of parts, which are responsible for different aspects of the system. It is important to integrate, combine and manage them together in order to create consistent application running in the Slow Control system cabinets. Prototype of that project will be presented in this presentation.
Go to contribution page -
Mr Maciej GrudziążStudent program: TeFeNica, Team for the Future of NICA Dubna 2017Talk
The usage of the Compact RIO cassette in Slow Control system with RACK cooling system as an example.
Go to contribution page -
Mr Marcin Birski (University of Wrocław)World experiments...Talk
The MPD (Multi Purpose Detector) is a part of NICA (Nuclotron Ion Collider fAcility) project in Dubna (Russia). Among many control systems, SCS (Slow Control System) is dedicated to handle and control parameters of the detector, which vary with relatively slow sample rate and do not depend on experiment being carried out.
Go to contribution page
I am going to describe on part of the rack network analyser control... -
Tomasz LehmannStudent Program: SCS-2017 Slow Control System Dubna 2017Talk
NICA (Nuclotron-based Ion Collider fAcility) is an accelerator complex designed in Dubna for the Joint Institute for Nuclear Research. The main task of that project is the examination of properties of dense baryonic matter.
Go to contribution page
The most important problems considered during NICA’s experiments are:
- the nature and properties of strong interactions between elementary constituents of the Standard... -
Daniel Dabrowski (Warsaw University of Technology), Krystian Roslon (Warsaw University of Technology (PL)), Marek Peryt (Warsaw University of Technology)Student Program: SCS-2017 Slow Control System Dubna 2017Talk
The MPD (Multi Purpose Detector At NICA) experiment which is under construction at Laboratory of High Energy Physics at Joint Institute for Nuclear Research will be studying relativistic heavy ion collisions. Such experiments produce not only experimental data but also variety of operational parameters which should be monitored and controlled during regular functioning. For this purpose Slow...
Go to contribution page