4–6 Jun 2018
Hamburg
Europe/Zurich timezone

Charge Collection Efficiency of proton-irradiated small-cell 3D strip sensors up to 1.7E16 neq/cm2 equivalence fluence

5 Jun 2018, 14:50
20m
Deck 10 (International Maritime Museum, Hamburg)

Deck 10

International Maritime Museum, Hamburg

Speakers

Mrs Andrea García Alonso (IFCA) Andrea Garcia Alonso (Universidad de Cantabria (ES))

Description

A study of Silicon strip 3D sensors of sizes 50 um x 50 um and 25 um x 100 um, fabricated at CNM using double-sided technology is shown. Sensors are wire-bonded to ALIBAVA read-out system. Results about charge collection of non irradiated sensors are presented, and also irradiated up to fluences of 1.7E16. The response of the sensors in both a test beam of 120 GeV protons and pions, and radioactive source 90Sr measurements is analyzed.

Primary author

Presentation materials