Conveners
Poster Session 5 (Gas-based Detectors; Medical Applications of Position Sensitive Detectors)
- Konstantinos Nikolopoulos (University of Birmingham (GB))
- Tony Price (University of Birmingham (GB))
Description
Gas-based Detectors
Medical Applications of Position Sensitive Detectors
The Monitored Drift Tube detector technology is used in the ATLAS experiment for the very accurate, reliable muon tracking and momentum measurements in the barrel and endcap regions. Already in Run 2 of the LHC they had to cope with very high background counting rates up to 500 $Hz/cm^2$ in the inner endcap layer. At High-Luminosity LHC, the background rates are expected to increase by almost...
Micro-pattern gaseous detectors (MPGDs) can operate at very high particle flux demonstrating consistently high efficiency and coordinate resolution in tens microns scale. Tracking MPGDs are developed and applied in several experiments at Budker INP.
Eight two-coordinate cascaded Gas Electron Multiplier based detectors (GEM-detectors) have been working at the Tagging System of KEDR experiment...
The thin-scintillator ion beam imager (SIBI) is a novel charged particle imaging detector developed by our group for various applications. It uses proprietary high light-yield, very thin (<500 µm) hybrid inorganic scintillator sheets or ultra-thin (3-200 µm) organic scintillator films. The scintillation elements are coupled by low f-number optics to high sensitivity, low-noise or ultra-low...
We will report first performance results for a prototype PET system designed for proton rage verification in proton therapy. This prototype will later be evaluated with phantoms and animals at the proton therapy center of MD Anderson Cancer Centre in Houston, Texas, USA.
The PET system consists of two detector module assemblies in the shape of angular sections of a cylinder with an inner...
Reduction of random and scatter events contributing to the background on the reconstructed image is important in PET imaging. Two gamma rays from annihilation of para-positronium containing anti-parallel spins are entangled and have orthogonal linear polarization. The orthogonal linear polarization in two correlated photons results in the difference between azimuthal scattering angles of two...
Silicon Photomultipliers are compact single-photon-sensitive detectors, widely used in many applications. In FBK (Trento, Italy) we developed large area SiPMs (up to 10x10$mm^2$), based on different technologies and we are also focusing on the position-sensitive SiPM (PS-SiPM) technology based on charge-sharing approach. These are based on the so called “linearly-graded, LG” technology,...
To improve medical treatment, the medical imaging field needs to develop more accurate imaging modalities. Using a Compton camera that has the ability to image a wide energy gamma-ray, has a wide field of view with a good angular resolution and electronically collimated, could help to improve medical treatments. To investigate physiological bodily functions, nuclear medicine imaging uses a...
The instantaneous luminosity of the Large Hadron Collider at CERN will be increased by about a factor of five with respect to the design value by undergoing an extensive upgrade program over the coming decade. The largest phase-1 upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the New Small Wheels (NSWs) during the long-LHC...
The high luminosity expected from the HL-LHC will provide a great opportunity for precise physics measurements and searches for new physics. Nevertheless, the increased rate of particles coming from the collisions will pose a challenge for the CMS detectors.
To prepare the muon system for the challenging conditions during the high luminosity phase, several upgrades have been planned and are...
The ORIGIN project aims to deliver photonics-enabled, adaptive, and more effective diagnostics-driven brachytherapy for cancer treatment through advanced real-time radiation dose imaging and radioactive source localization. This goal will be achieved by developing a 16 to 32 optical-fiber-based system where scintillating light is detected by Silicon Photomultiplier. This work reports the...
Proton therapy is a treatment method that utilizes the energy deposition of heavy ions to concentrate the dose delivered to a patient during the treatment of the malignant tumor. The Bergen proton Computed Tomography (pCT) collaboration is constructing a prototype detector capable of both tracking and measuring the energy deposition of ions in order to minimize uncertainty in proton treatment...
Gas Electron Multiplier (GEM) detectors are a prominent example of Micro-Pattern Gaseous Detectors (MPGDs). One of their main features is that they provide a good spatial resolution over large areas (square metre sized detector modules). When the interacting particle deposits energy inside the detector volume, primary electrons are created that drift towards the readout anode (here: 9 mm drift...
Drift Tubes (DT) detectors equip the CMS muon system barrel region serving both as offline tracking and triggering devices. Existing DT chambers will operate throughout High-Luminosity LHC, but, in order to withstand event rates and integrated doses far beyond the initial design specification, an upgrade of the current readout and trigger electronics is planned. In the upgraded system,...
Positron emission tomography (PET) is one of the most important diagnostic tools in medicine, providing three-dimensional imaging of functional processes in the body. The method is based on detecting two gamma rays originating from the point of annihilation of the positron emitted being by radio-labelled agent, and used to follow the human's physiological processes. In Time-Of-Flight PET gamma...
This work illustrates some recent advances based on the so-called MicroScint, a technology developed by CERN and EPFL in recent years aimed to realize a beam transverse profiler with high spatial resolution based on a microfluidic device, obtained by a standard Silicon microfabricated structure filled with an organic liquid scintillator. The signals at each channel’s segments end are readout...
The CMS Resistive Plate Chambers (RPC) system has been certified for 10 years of LHC operation. In the next years, during the High luminosity LHC (HL-LHC) phase, the LHC instantaneous luminosity will increase to factor five more than the nominal LHC luminosity. This will subject the present CMS RPC system to high background rates and operating conditions much higher with respect those for...
Higher energy and intensity X-ray radiotherapy treatments are coming into wider use, having the benefit of requiring fewer treatment fractions and fewer hospital visits per patient. However, small percentage errors in MLC positioning and dose become bigger problems with higher doses per fraction. Hence, real-time treatment verification becomes essential. Where devices downstream from the...
Advanced imaging and treatment techniques in proton therapy allow conformal high dose irradiation of the target volume with high precision using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly include small radiation fields with large dose gradients at the edges, which require the development of new micro dosimetry systems with precise spatial resolution...
Low-dose CT (LDCT) usually reduces the dose by reducing tube current compared to the normal dose CT (NDCT), and this behavior is affected by lowering the signal-to-noise ratio (SNR), resulting in poor image quality. LDCT has negative characteristic of different noises (e.g., photon noise, electronic noise, anatomical noise, etc.). Because the image quality of low-dose CT is dominated by noise,...
The spherical proportional counter is a versatile gaseous detector with physics applications ranging from rare event searches to fast neutron spectroscopy. In its simplest form, the detector operates with a single channel readout and uses pulse-shape information to reconstruct the interaction radius, which is used for background discrimination and fiducialisation. Recent developments in the...
The accurate analysis of breast imaging is important because it has been reported that an increase in breast density of only 1% results in a 2% increase in the relative risk of breast cancer. The proteins, water, and lipids that determine breast density are important biomarkers in the diagnosis of breast cancer. In mammography, photon-counting detectors (PCDs) with energy-discrimination...
Gas-based detectors Micromegas are used in many high energy physics experiments to track charged particles. They can cover large areas with homogeneous gain, providing spatial resolution from millimeter to tenth of millimeter.
Micromegas can be read along one projection with strips (1D) or two projections with pads interconnected (2D), but the resolution highly depend of the density (pitch)...
For 3D-tracking and identification of low-energy electrons a new type of gas-based detector was designed that minimizes scattering and energy loss.The current version of the detector is a combination of a plastic scintillator,serving as a trigger source,and a hexagonally structured multi-wire drift chamber(MWDC),filled with a mixture of helium and isobutane gas.The drift time information is...