20–24 Sept 2021
America/Vancouver timezone

Highly Time-Resolved Emittance Measurement for a High-Intensity H- Beam Extracted from a 2 MHz RF-Driven H- Ion Source

Not scheduled
20m
Poster Beam extraction, transport, and diagnostics Poster Session 2

Speaker

Katsuhiro Shinto (Japan Atomic Energy Agency)

Description

In most of proton accelerator facilities, H- ion sources with driving 2-MHz RF amplifiers for plasma production generate high-intensity H- beams. Because of the high plasma density in the ion source, the potential of the sheath adjacent to the plasma electrode may be oscillated with the RF driving frequency. We showed a low frequency oscillation of the beam current (AIP CP, 2011, 080016 (2018)) and the beam profile (Rev. Sci. Instrum., 91, 013330 (2020)).
We have been developing a highly time-resolved emittance measurement system in order to measure the fluctuation in association with the frequency of the rf source. The system is equipped with a low-noise differential FET amplifier with the frequency range up to 70 MHz and a digitizer with sampling rate of 60 MS/s enough to observe the fundamental and higher-harmonics fluctuation occurred by the RF source.
In this conference, we will show some results of obtained emittance fluctuation by using the system and discussion of possible mechanisms.

E-mail for contact person kshinto@post.j-parc.jp
Funding Information Japan Society for the Promotion of Science, KAKENHI 17K05108

Primary authors

Katsuhiro Shinto (Japan Atomic Energy Agency) Motoi Wada (Doshisha University) Takanori Shibata (KEK)

Presentation materials

There are no materials yet.