Conveners
A5a - Packaging and Interconnects
- Jorgen Christiansen (CERN)
-
Paolo Petagna (CERN)29/09/2011, 09:50PackagingOralMicro-channel cooling is gaining considerable attention as an alternative technique for cooling of high energy physics detectors and front-end electronics. We are evaluating this technology for future tracking devices where material budget limitations are a major concern. Micro channel cooling is currently under investigation as an option for the cooling of the NA62 Gigatracker silicon pixel...Go to contribution page
-
Mr Michael Woods (University of California Davis)29/09/2011, 10:15PackagingOralThe SiD collaboration is developing a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve bonding technologies for the interconnects, especially silicon detector wafer to a flex-cable readout bus attachments. We review the interconnect technologies involved, including oxidation...Go to contribution page