Speaker
Description
Cryopumps are used as the main pumps of cryo-vacuum systems in the Negative Neutral Beam Injectors (NNBI) test facility to pump gas to generate and maintain the vacuum gradient environment. To cool the cryopumps, a 1000 W@4.5K cryogenic system was built, which provides 4.5 K supercritical helium for cryopanels and 77 K liquid nitrogen for radiation baffles. The major cryogenic system components include helium recycle compressor, oil removal system (ORS), cold box, LHe Dewar, cryogenic distribution box, recovery compressor, helium purifier, gas bag, helium tanks, and LN2 tanks. Design, fabrication, and installation of most of the 1000W@4.5K helium refrigerator was carried out at ASIPP. This paper presents an overview of the design, installation and commissioning of the cryogenic system for NNBI test facility.
Submitters Country | P.R.China |
---|