Conveners
Trigger: B3a
- Wesley Smith (University of Wisconsin (US))
Marco Ghibaudi
(Scuola Superiore Sant'Anna di Studi Universitari e di Perfezion)
25/09/2013, 09:50
Oral
The Central Trigger Processor (CTP) is the final stage of the ATLAS first level trigger system which reduces the collision rate of 40 MHz to a Level-1 event rate of 100 kHz. An upgrade of the CTP is currently underway to significantly increase the number of trigger inputs and trigger combinations, allowing additional flexibility for the trigger menu.
We present the hardware and FPGA firmware...
Marian Krivda
(University of Birmingham (GB))
25/09/2013, 10:15
Oral
After three years of successful operation of Alice Central Trigger Processor (CTP) system for proton-proton, Pb-Pb and p-Pb collisions, the Alice CTP is going to be upgraded with a new L0 board in order to improve the performance of the Alice trigger system. The new L0 board will include several new features: an additional trigger level "LM", which will precede the L0 trigger and will improve...