At an instantaneous luminosity of 5 × 1034 cm−2 s−1, the high-luminosity phase of the Large Hadron Collider (HL-LHC) is expected to deliver a total of 3000 fb−1 of collisions, hereby increasing the discovery potential of the LHC experiments significantly. However, the radiation dose of the tracking systems will be severe, requiring new radiation hard sensors for the CMS tracker. The CMS...
Andreas Matthias Nurnberg
(KIT - Karlsruhe Institute of Technology (DE))
14/11/2013, 10:05
In the CMS campaign to find the new baseline material for the next tracker, irradiated p-on-n sensors showed a non-gaussian noise behaviour. The effect has been quantified and studied systematically as a function of the applied bias voltage and sensor annealing, as well as irradiation fluence, particle type and energy and sensor geometry. In some operation area, this effect would lead to an...
Marcela Mikestikova
(Acad. of Sciences of the Czech Rep. (CZ))
14/11/2013, 10:55
Electrical tests of ATLAS12A EndCap mini sensors manufactured by HPK were performed in Freiburg, Prague and Valencia. Results of leakage current and full depletion voltage as well as coupling capacitance, bias resistance, inter-strip capacitance and resistance and punch-trough measurements on non-irradiated sensors will be presented.
Vitaliy Fadeyev
(University of California,Santa Cruz (US))
14/11/2013, 11:15
We are working on the proposed small angle calorimeter for ILC, "BeamCal". The detector, which is envisioned as a tungsten sandwich calorimeter, will be subject to high fluences EM radiation that will shower in the tungsten radiator. We are doing studies that explore the effects of radiation damage on candidate sensors at shower-max within the induced shower. In addition to electrons,...
Dr
Miguel Ullan Comes
(Universidad de Valencia (ES))
14/11/2013, 11:35
An update will be presented on the status of the LowR project. General performance results from the first Low-R sensors fabricated at the clean room of CNM-Barcelona will be shown (technological parameters, IV, CV). Results on the tests on other important sensor parameters like strip resistance, inter-strip isolation, and pulse shape will also be presented. First tests on the PTP structures...