Speaker
Dr
Christoph Affolderbach
(University of Neuchatel, LTF)
Description
Compact Rb vapor-cell atomic clocks are high-stability frequency references for applications ranging from telecommunication to satellite navigation systems. For achieving state-of-the-art clock operation, stringent requirements apply to the microwave resonator cavity used in the clock. Here we report on a compact microwave cavity produced by additive manufacturing of a polymer followed by metal coating. Using this cavity we demonstrate Rb clock operation in both the continuous-wave and pulsed Ramsey scheme [1]. The microwave field distribution inside the cavity is assessed experimentally using the Rb atomic vapor as a probe inside the cavity.
[1] Applied Physics Letters 112, 113502 (2018).