Timing Resolution of SiPM technologies before and after neutron irradiation

10 Jul 2019, 14:25
15m

Speaker

Mr Shashank Kumar (Central Institute of Engineering, Electronics and Analytics ZEA-2 – Electronic Systems, Forschungszentrum Jülich GmbH)

Description

Timing Resolution of SiPM technologies before and after neutron irradiation
S. Kumar1, L. Niraula1, M. Herzkamp1, D. Arutinov1, S. van Waasen1,2
1 Central Institute of Engineering, Electronics and Analytics ZEA-2 – Electronic Systems,
Forschungszentrum Jülich GmbH, 52425 Jülich, Germany
2 Faculty of Engineering, Communication Systems (NTS), University of Duisburg-Essen,
47057 Duisburg, Germany

E-mail: s.kumar@fz-juelich.de

ABSTRACT
In recent years, silicon photomultiplier (SiPM) technology is getting attention from various applications due to its low cost, immunity to magnetic field, compactness and ruggedness. However, its applicability in experiments with harsh radiation environments is still limited due to lack of corresponding radiation damage studies. A typical 10-year lifetime operation in a typical Small Angle Neutron Scattering experiment [1] with an acceptable PDE degradation [2] has already been reported, and in this study, the timing resolutions of SiPMs before and after exposure with cold neutrons (5 Å) were compared. For this purpose, two analog SiPMs, developed by SensL and Hamamatsu, and a digital SiPM manufactured by Philips Digital Photon Counting were irradiated up to a dose of 6E12n/cm2 at the KWS-1 instrument of the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching.
The used measurement system consists of a 403 nm Laser with a pulse width of 45 ps FWHM, and an oscilloscope (40 GS/s, 14 GHz) for data acquisition. During the characterization campaign, a time resolutions has been measured using ~500 photon pulses impinging on the SiPMs, which were kept under constant temperature of 21 °C. The first result of SensL SiPM show no significant difference in jitter values before and after irradiation up to a dose of 1.9E12 n/cm2. The performed tests provide an insight into feasibility of implementing SiPM based fast and efficient scintillation light detectors for applications such as neutron time-of-flight scattering experiments.

Author

Mr Shashank Kumar (Central Institute of Engineering, Electronics and Analytics ZEA-2 – Electronic Systems, Forschungszentrum Jülich GmbH)

Co-authors

Mr Lokesh Niraula (aCentral Institute of Engineering, Electronics and Analytics ZEA-2 – Electronic Systems, Forschungszentrum Jülich GmbH) Dr Matthias Herzkamp (Central Institute of Engineering, Electronics and Analytics ZEA-2 – Electronic Systems, Forschungszentrum Jülich GmbH) Mr David Arutinov (Central Institute of Engineering, Electronics and Analytics ZEA-2 – Electronic Systems, Forschungszentrum Jülich GmbH) Prof. Stefan van Waasen (Central Institute of Engineering, Electronics and Analytics ZEA-2 – Electronic Systems, Forschungszentrum Jülich GmbH)

Presentation materials