Speaker
Description
Schottky cavity pick-ups have proven to be fast and sensitive detectors
for use in storage ring experiments with radioactive ion beams (RIB)
relevant for nuclear astrophysics [1]. Cavity pick-ups with longitudinal
sensitivity have been successfully used in the storage ring ESR in GSI
facility [2-4], CSRe in Lanzhou [5] and in R3 ring in RIKEN [6]. Some
initial studies were carried out in order to extend the concept to
sensitivity in transverse direction for use in different storage rings
[8-10]. In the current work we report on the progress of the modelling
of a prototype of a position-sensitive resonant Schottky cavity for the
R3 storage ring in the RIKEN facility.
References
[1] Litvinov Yu. A. et al. 2013 Nucl. Instrum. Meth. B 317
[2] Sanjari M. S. et al. 2013 Phys. Scr. T156
[3] Sanjari M. S. et al. 2020 submitted to Rev. Sci. Instrum.
[4] Kienle P. et al. 2013 Phys. Lett. B 726 4–5
[5] Wu J. et al. 2013 Nucl. Instrum. Meth. B 317
[6] Suzaki F. et al. 2015 Phys. Scr. T166
[7] Sanjari M. S. et al. 2015 Phys. Scr. 014060
[8] Chen X. et al. 2016 Nucl. Instrum. Meth. A 826
[9] Chen X. et al. 2015 Hyperfine Interact. 5
[10] Dmytriiev D. et al. 2020 Nucl. Instrum. Meth. B 463