Description
An aluminium stabilized superconducting cable is developed for the Circular Electron Positron Collider(CEPC) detector magnet. In order to measure the critical current of the prototype cable, an inductive method is developed: the cable is closed in a low resistance loop forming the secondary coil of a transformer, while the 6 Tesla background magnet serves as the primary.
The critical current is measured for the prototype cables before and after co-extrusion to ensure that the degradation from this progress meet the design requirements.