Indico celebrates its 20th anniversary! Check our blog post for more information!

11–13 Jun 2014
Bucharest
Europe/Zurich timezone

Evaluation of the Low Resistance Strip Sensors Fabricated at CNM

13 Jun 2014, 15:20
20m
Bucharest

Bucharest

Speaker

Dr Miguel Ullan Comes (Instituto de Fisica Corpuscular (ES))

Description

Results from the second batch of Low-R strip sensors fabricated at CNM-Barcelona will be presented. This second batch implements several technological and design changes in order to correct the PTP structure, not fully functional in the first batch. The tests on the newly fabricated sensors show good general performance plus a correct behaviour of the PTP structure. The results from the laser tests show the proper limitation on the strip voltage in the event of a beam-loss even when the change injection is produced far from the PTP structure for the Low-R strip sensors. This strip voltage limitation is not seen for the standard sensors also fabricated in the same wafer. This demonstrates the effectiveness of the proposed low resistance strip. Finally, alternative technological implementations for the Low-R sensors will be presented. These solutions are in fabrication at the moment at CNM.

Primary author

Dr Miguel Ullan Comes (Instituto de Fisica Corpuscular (ES))

Co-authors

Dr Alex Grillo (University of California,Santa Cruz (US)) Carlos Lacasta Llacer (IFIC-Valencia) Giulio Pellegrini (Universidad de Valencia (ES)) Hartmut Sadrozinski (SCIPP, UC santa Cruz) Manuel Lozano Fantoba (Instituto de Fisica Corpuscular (ES)) Victor Hugo Benitez Casma (Instituto de Fisica Corpuscular (ES)) Vitaliy Fadeyev (University of California,Santa Cruz (US))

Presentation materials