25–29 Sept 2006
Valencia, Spain
Europe/Zurich timezone

Radiation tests for Slow Control ALICE TOF systems

27 Sept 2006, 16:20
1h 40m
Valencia, Spain

Valencia, Spain

IFIC – Instituto de Fisica Corpuscular Edificio Institutos de Investgación Apartado de Correos 22085 E-46071 València SPAIN

Speaker

Pietro Antonioli (INFN - sezione di Bologna)

Description

The read-out modules of the ALICE Time-of-flight (TOF) system will be hosted in custom VME crates near the apparatus in a moderately hostile environment. Commercially available options to provide remote VME connection to the crate have been considered to provide slow control functionalities. The main slow control channel will be implemented through an optical link based on the commercial cards A2818/V2718 from CAEN for front-end electronics configuration and monitoring purposes. An additional ethernet link to an ARM CPU running Linux will be available. Radiation tolerance test results for the critical components corresponding to the abovementioned choices will be presented, as well as estimates of the minimum time between failure while taking data. The results presented here can be used to estimate upset rates for specific applications of commercially available VME controller cards and Single Board Computer like the CAEN V2718 and A1500.

Summary

The ALICE Time-of-flight (TOF) system will be a large area (140 m2)
detector made OF Multigap Resistive Plate Chambers (MRPC) installed in
the barrel region. The read-out modules will be hosted in custom VME
crates near the apparatus in A moderately hostile environment (1.2 Gy
expected in 10 years of operation). Data collected will be sent to the
central DAQ through the custom optical link developed within the ALICE
collaboration (ALICE DDL).

The choice VME bus as the backbone to house the readout electronics
ALLOWS for commercial options to provide remote VME connection to the
crate and to provide slow control functionalities.
The design of the slow control system to access the VME bus while taking
data has been thoroughly investigated with respect to radiation tolerance
issues.

The main slow control channel will be implemented through an optical link
based on the commercial cards A2818/V2718 from CAEN for front-end
electronics configuration and monitoring purposes. An additional ethernet
link to an ARM CPU (which will be mainly responsible for firmware
upgrade), running Linux, will be available.

Radiation tolerance test results for the critical components,
corresponding to the above mentioned choices, will be presented. We used,
at the CRC Louvain facility, a proton beam OF 60 MeV energy. We
irradiated all devices under tests with a total dose of 10 Krad. No
latchups have been observed for all the components tested.

The components tested include: optical transceiver HFBR-5911L (from
Agilent) coupled to two different SerDes: Pericom HDMP-1636 and Agilent
PI90SD1636A.
The total cross sections of the optical link for SEU were measured :
1.9E-9 cm2 and 3.3E-9 cm2 respectively, allowing to select the more
radiation tolerant SerDes for the final card. FOR all errors observed the
communication was quickly re-established after a simple reset (managed by
the Linux driver on the receiving PC).

The ARM processor was originally foreseen to handle firmware upgrade for
TDC cards through a custom bus on the VME backplane and not to be
operated while taking data and under irradiation.

Due to the fact that we measured for the ARM processor AT91RM9200 from Atmel
a device cross section equal to 1.0E-9 cm2 for operating system
failures, we plan to use now the card also as a backup slow control link.

For both slow control solutions we actually obtained an estimate of
minimum time between failure while in data taking, which is around 20
hours for the whole TOF detector, where 72 slow control optical links
will be deployed.

We then tested, for the final card, also the FPGA normally used by CAEN
for the V2718 (Altera Cyclone, which has built-in CRC error monitoring
for configuration bits) and different memory chips, to be used to stage
data during data collection. The result for the Cyclone (cross section
9.0E-9 cm2/device) is very similar to a previous result obtained for
an Altera Stratix, when normalized to the configuration bits.

Besides the specific technical solutions adopted in the final VME ALICE
card (Data Readout Module, which will host other LHC specific chips,
like the TTCrx), the results presented here can be used to estimate
upset rates for specific applications of commercially available VME
controller cards and Single Board Computer like the CAEN V2718 and A1500.

Primary author

Pietro Antonioli (INFN - sezione di Bologna)

Co-authors

Annalisa Mati (CAEN) Carlo Tintori (CAEN) Maura Pieracci (CAEN) Mirco Zuffa (INFN - sezione di Bologna) Stefano Coluccini (CAEN) Stefano Meneghini (INFN - sezione di Bologna)

Presentation materials

There are no materials yet.