  1. Jing Yang
    16/11/2021, 13:15
    Poster

    In this paper we show that the design of specialized rotating coil system to measure magnetic Axis of the triplet quadrupoles whose magnetic axis deviation are less than 0.1mm and angle deviation are less than 1mrad between them, built for DTL of a Linear accelerators. In this paper we describe the design of the rotating coils canceling the first two field harmonics, and the process of the...

    Go to contribution page
  2. Mr Shogo Murakami (Waseda University)
    16/11/2021, 13:15
    Poster

    We have been developing a no-insulation (NI) REBCO coil system for medical accelerators and high-field magnetic resonance imaging (MRI). There are increasing attempts to apply NI winding technology to achieve both high current density and high thermal stabilization of REBCO coils. However, REBCO coated conductor has a tape shape, and when a magnetic field is applied vertically to the tape...

    Go to contribution page
  3. Xiaorong Wang (Lawrence Berkeley National Laboratory)
    16/11/2021, 13:15
    Poster

    The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is developing MQXFA magnets, a series of 4.5 m long 150 mm aperture high-field Nb$_3$Sn quadrupole magnet for the Hi-Luminosity LHC upgrade at CERN. Five Pre-Series magnets, MQXFA03 through MQXFA07, have been developed. During the magnet assembly stage, we perform magnetic measurements of the coil packs and magnets to track...

    Go to contribution page
  4. JACOB ROCHESTER (The Ohio State University)
    16/11/2021, 13:15
    Poster

    Bi:2212 superconducting cables are being considered for use in high field magnets such as those in the next generation of particle accelerators. However, a comprehensive understanding of their behavior is necessary before full-scale magnets can be constructed. The magnetization and flux creep in the superconductor can lead to significant field errors which need to be compensated. To study...

    Go to contribution page
  5. Joseph DiMarco (Fermilab)
    16/11/2021, 13:15
    Poster

    LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass installed within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab’s...

    Go to contribution page
  6. Kodai SHIRAI (Waseda University)
    16/11/2021, 13:15
    Poster

    Targeted alpha-particle therapy is a cancer treatment method using alpha-emitting radioisotope (RI), and is expected as a treatment method for progressive cancer. We are conducting research toward the development of a High-temperature-superconducting Skeleton Cyclotron (HTS-SC), which is an ultra-compact and high-intensity accelerator capable of stably producing the alpha-emitting...

    Go to contribution page
  7. Michael Green (Lawrence Berkeley Laboratory)
    16/11/2021, 13:15
    Poster

    It has been fifty years since the first papers on the effects of magnetization in the superconductor in an accelerator magnet field quality were measured. The effects of conductor magnetization are most pronounced at low fields. By late 1971, a reliable method for estimating the effects of superconductor magnetization on the field quality in accelerator magnets was developed. A review of...

    Go to contribution page
  8. yan bing Yang (Institute of Modern Physics. Chinese Academy of Sciences)
    16/11/2021, 13:15
    Poster

    The magnetic center alignment is extraordinarily important before put a new ion-source into operation. Misalignment of ion-source may cause arc chamber destroyed. We take two methods to measure and align the ion-source superconducting magnet based on the cryostat bore in IMP. The required offset between ion-source magnetic center and mechanical center of warm bore is less than 0.5mm.
    ...

    Go to contribution page