Ioannis Kaissas (Nuclear Technology Laboratory, School of Electrical & Computer Engineering, Aristotle University of Thessaloniki, University Campus, 54124 Thessaloniki, Greece)29/06/2026, 16:50ApplicationsPoster presentation + pitch
ฮณ-cameras with coded apertures have been proved to be an efficient method to identify weak ฮณ-radioactive sources in three-dimensional space, providing planar images with sufficient spatial resolution and signal-to-noise ratio [1]. In this work, we attempted a single-photon-emission computerized tomography with the filtered-back-projection method, exploiting planar images derived by a...
Go to contribution page -
Dr Pavel Zabrodin (Czech academy of sciences, Institute of theoretical and applied mechanics)29/06/2026, 17:05ApplicationsPoster presentation only
During energy-dispersive X-ray diffraction, the sample is irradiated with a pencil beam generated by a standard polychromatic X-ray tube without any spectral filtering. Two-dimensional polychromatic diffraction images are acquired using a Timepix 3 quad CdTe detector with a central aperture to allow the pencil beam to pass through without parasitic interaction. The detector, equipped with a...
Go to contribution page -
Patrice Schlegel (German Cancer Research Center (DKFZ))29/06/2026, 17:101ApplicationsPoster presentation only
Introduction
Delivering Carbon-ion radiotherapy (CIRT) at consistently high accuracies throughout a multi-week treatment remains challenging in clinical practice. Even though the dose conformity of CIRT is exceptionally high, it always relates to the last known factual state of the patientโs anatomy, which gets increasingly uncertain the more time has passed since the Computed Tomography...
Go to contribution page -
Dr Wolfgang Treberspurg (University of applied Sciences Wiener Neustadt)29/06/2026, 17:10ApplicationsPoster presentation + pitch
In order to accurately characterize the flux of primary particles in medical accelerators, the signals of events due to primary and secondary particles need to be discriminated. Irradiation experiments often require high precise environment, in which the impact of secondary particles, generated downstream a beam dump or pin-hole configuration need to be considered.
We present the analysis...
Go to contribution page -
Tadeas Petru (Charles University (CZ))29/06/2026, 17:10ApplicationsPoster presentation only
The Tile Calorimeter (TileCal) is a sampling hadronic calorimeter covering the central region of the ATLAS experiment at the CERN Large Hadron Collider (LHC). It is composed of steel absorbers and plastic scintillators as the active medium, with scintillation light collected by wavelength-shifting fibres and read out by photomultiplier tubes. The stability of the calorimeter response is...
Go to contribution page -
Connor Darling (University College London, Francis Crick Institute)29/06/2026, 17:10ApplicationsPoster presentation + pitch
The National facility for lab-based X-ray Computed Tomography (NXCT) is a UK wide, cross-institutional initiative to provide access for both academia and industry to a range of x-ray CT equipment, techniques and expert support. A key aim of the facility is to enable new users to access the technique, including through a free-at-point of access scheme. It supports, for example, novel research...
Go to contribution page -
Yoonsang Hong (School of Mechanical Engineering, Pusan National University)29/06/2026, 17:10ApplicationsPoster presentation only
Scientific and engineering efforts in radiology aim to provide high-uality images at the lowest possible radiation dose. When this principle is applied to industrial imaging, the low-dose requirement can be interpreted as low-power operation of the x-ray source. Inspection of printed circuit boards (PCBs) requires real-time, prolonged operation of x-ray imaging systems; therefore,...
Go to contribution page -
Philip Pfaefflein (European XFEL)29/06/2026, 17:101ApplicationsPoster presentation only
The Heisenberg-RIXS spectrometer (hRIXS) at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL is dedicated to performing resonant inelastic X-ray scattering (RIXS) measurements in the time domain, with time and energy resolution approaching the Heisenberg limit imposed by the uncertainty relations [1, 2]. The spectrometer uses a dispersive element and requires a...
Go to contribution page -
Geunyoung An (Jeonbuk National University)29/06/2026, 17:101ApplicationsPoster presentation only
The global issue of contraband items, such as illicit narcotics and bombs, is becoming increasingly severe. Many countries use X-ray security screening at their borders to intercept these dangerous goods. Backscatter X-ray imaging techniques clearly display materials with low atomic numbers. However, the atomic numbers and densities of drugs and explosives are similar to those of common...
Go to contribution page -
Jan Broulim (Czech Technical University in Prague (CZ)), Karolina Lavickova (Czech Technical University in Prague (CZ))29/06/2026, 17:10ApplicationsPoster presentation only
The ColorPix ASIC, currently in its third revision, is a hybrid pixel detector designed for spectral X-ray imaging. It is implemented in 65 nm CMOS technology and features a 32 ร 32 pixel matrix, with scalability toward future expansion up to 256 ร 256 pixels. The pixel pitch is 70 ยตm. A 2 mm-thick CZT (cadmium zinc telluride) sensor layer, which is highly sensitive to X-rays, is bump-bonded...
Go to contribution page -
Michiko Tsuda (Takasaki Institute for Advanced Quantum Science, National Institutes for Quantum Science and Technology (QST))29/06/2026, 17:10ApplicationsPoster presentation + pitch
Positron emission tomography (PET) enables three-dimensional visualization of radioactive tracers in plants, but conventional systems are costly and not optimized for plant research. In this study, we characterized the count-rate performance of our low-cost plant-dedicated PET system and demonstrated dynamic imaging of living plants for the first time.Count-rate measurements using a carbon-11...
Go to contribution page -
Dr Konstantinos Karafasoulis (Hellenic Army Academy)29/06/2026, 17:10ApplicationsPoster presentation only
Portable low-resolution gamma-ray detectors are widely used at radiological crime scenes because they can be rapidly deployed in the field; however, reliable isotope identification remains challenging when spectra include overlapping emissions, background contributions, and limited counting statistics. Building on our previous deep learning framework for single-isotope identification [1] with...
Go to contribution page -
Seungjun Yoo (School of Mechanical Engineering, Pusan National University)29/06/2026, 17:10ApplicationsPoster presentation only
Film-based technology has long been the standard in industrial imaging; however, recent advances in artificial intelligence have accelerated the transition to digital imaging. Consequently, film digitizers have become necessary components in film-based workflows. Flat-panel detectors (FPDs), which inherently produce digital x-ray images, are increasingly replacing film in industrial...
Go to contribution page -
Tomoyuki Ishiwatari (Graduate School of Science and Technology, Gunma University / Takasaki Institute for Advanced Quantum Science, National Institutes for Quantum Science and technology)29/06/2026, 17:10ApplicationsPoster presentation only
PETIS (Positron Emitting Tracer Imaging System) enables real-time, non-destructive visualization of substance distribution in plants. However, the spatial resolution of conventional PETIS instruments (FWHM โ 1.6โ2.1 mm) is insufficient for resolving fine structures such as leaf veins and internodes. Therefore, this study aims to develop a compact PETIS instrument that achieves both high...
Go to contribution page -
Haruki Iiyama (Yamagata University)29/06/2026, 17:10ApplicationsPoster presentation only
MeV gamma-ray observations are a probe for various physical phenomena, including searches for dark matter and primordial black holes, and nucleosynthesis in the Universe. In order to achieve high sensitivity in this band, we are developing an electron-tracking Compton camera (ETCC), which combines a gaseous time projection chamber (TPC) and pixelated GSO(Ce) scintillator arrays (PSAs). The TPC...
Go to contribution page -
Georgios Mystridis (University of Foggia, Fondazione Bruno Kessler)29/06/2026, 17:10ApplicationsPoster presentation only
Please see attached PDF
Go to contribution page -
David Lomidze (European XFEL)29/06/2026, 17:10ApplicationsPoster presentation only
Advanced soft X-ray imaging at the European XFEL demands a unique combination of ultra-low noise, high dynamic range, and MHz frame rate. The DSSC (DEPFET Sensor with Signal Compression) detector has been developed to meet these requirements in the 0.5โ6 keV range, enabling the detection of soft X-ray scattered photons at repetition rates up to 4.5 MHz [1]. While the existing 1-megapixel DSSC...
Go to contribution page -
Ho Kyung Kim (School of Mechanical Engineering, Pusan National University)29/06/2026, 17:101ApplicationsPoster presentation only
A photon-counting detector (PCD) typically consists of a top sensor layer and a bottom electronics layer arranged in tandem. The sensor layer detects an incident x-ray photon and converts it into charge carriers, the number of which is proportional to the deposited energy. The bottom application-specific integrated circuit (ASIC) senses the resulting charge drift as a current, converts it into...
Go to contribution page -
Ali Khalilzadeh29/06/2026, 17:10ApplicationsPoster presentation only
Hydrogenated amorphous silicon (a-Si:H) and crystalline silicon photodiodes are promising candidates for radiation detector applications, including pixel detectors for proton therapy. In this work, we present a comparative electrical characterization of available photodiode samples with different material platforms and thicknesses, a-Si:H devices with thicknesses of 1.0 ยตm and 0.8 ยตm, and a...
Go to contribution page -
Jan Jakubek29/06/2026, 17:10ApplicationsPoster presentation only
In this contribution, we demonstrate a rather unusual application of X-ray diffraction (XRD) for the analysis of biological samples. We show that muscle, fat, tendon, and bone tissues produce distinct XRD patterns. It is further demonstrated that even thick, complex biological structures, such as a chicken wing, can be scanned using this technique. These measurements are enabled by fully...
Go to contribution page -
Ana Luisa Monteiro Da Silva (University of Aveiro (PT))29/06/2026, 17:10ApplicationsPoster presentation only
In this work, we present a novel energy-dispersive X-ray Fluorescence Computed Tomography (ED-XFCT)
Go to contribution page
system based on a Micro-Pattern Gaseous Detector (MPGD), exploring its potential as a flexible and cost-effective
alternative for 3D energy-resolved imaging.
The system integrates an X-ray tube source, a motorized rotation stage, and a 2D-THCOBRA detector operating
in single-photon counting... -
Prof. Yong Hyun Chung (Yonsei univ.)29/06/2026, 17:10ApplicationsPoster presentation only
The use of radioactive materials has been expanding across various fields, increasing the risk of radiation accidents, such as loss or theft. In such cases, a monitoring system capable of both source localization and radionuclide identification is essential [1]. However, conventional directional radiation monitoring systems are limited by a narrow field of view and difficulty in real-time...
Go to contribution page -
Aluizio Jose Salvador29/06/2026, 17:10ApplicationsPoster presentation only
Mogno is a microCT beamline at the Brazilian Synchrotron Light Source designed for full-field imaging with hard X-rays (67.5 keV) in a cone-beam geometry, enabling the investigation of samples with dimensions of up to several centimetres. The beamline is equipped with a large-area CdTe Pimega detector, composed of a 6 ร 6 array of Medipix3RX ASICs, providing a total sensitive area of 85 ร 85...
Go to contribution page -
Michiko Tsuda (Takasaki Institute for Advanced Quantum Science, National Institutes for Quantum Science and Technology (QST))29/06/2026, 17:10ApplicationsPoster presentation only
Particle therapy delivers highly localized doses via the Bragg peak, but therapeutic outcomes depend critically on beam range accuracy. Secondary electron bremsstrahlung (SEB), generated along the beam trajectory, has been proposed for beam range verification; however, insufficient detection sensitivity remains a key limitation. In this study, we investigated a knife-edge slit collimator,...
Go to contribution page -
Daniel Estrada (Universidad de Oviedo (ES))29/06/2026, 17:10ApplicationsPoster presentation only
To meet the extreme data demands of the High-Luminosity LHC, the LCH experiments are deploying enhanced trigger architectures built on next-generation hardware. This infrastructure is engineered to handle several tenths of Tb/s with ultra-low latency of O(ฮผs). Leveraging this processing power, offline-style algorithms that were previously beyond the computational reach of the online trigger...
Go to contribution page -
Mitsutaka Yamaguchi (Takasaki Institute for Advanced Quantum Science, National Institutes for Quantum Science and Technology)29/06/2026, 17:101ApplicationsPoster presentation only
We developed a secondary electron bremsstrahlung (SEB) camera for noninvasive beam range monitoring in particle therapy. The system uses a 22ร22 segmented GAGG:Ce scintillator array coupled with an 8ร8 SiPM array, read out by the TOFPET2 ASIC, which enables individual channel readout at high count rates. Beam tests with a 290 MeV/u carbon-ion beam at GHMC confirmed that the camera can...
Go to contribution page -
Ryan Parsons (H3D, Inc.)29/06/2026, 17:10ApplicationsPoster presentation only
Room-temperature CdZnTe semiconductor detectors are becoming commonplace in medical imaging, high-energy physics, and homeland security radiation measurements. The direct conversion of incident photons into charge carriers provides much higher limiting spatial and energy resolution than scintillation-based detectors. CdZnTe detectors are commonly pixelated to precisely measure the incident...
Go to contribution page -
Jiri Volny29/06/2026, 17:10ApplicationsPoster presentation only
Photon-counting X-ray detectors based on Medipix/Timepix technology are well established as powerful tools for high-resolution imaging. Their hybrid architecture, combining a pixelated semiconductor sensor with a dedicated CMOS readout ASIC, enables excellent spatial resolution, low noise, high count-rate capability, and flexibility in the choice of sensor material. These features make the...
Go to contribution page -
Robine Janssen (Ghent University)29/06/2026, 17:10ApplicationsPoster presentation + pitch
Purpose
Go to contribution page
Positron emission tomography (PET) enables functional imaging of tissues and organs. Long axial field-of-view (LAFOV) PET systems provide high-quality images with reduced scan times and lower patient dose. However, their widespread clinical adoption is limited by cost. The MEDISIP group is developing a cost-effective LAFOV PET design consisting of two vertical flat detector panels... -
ๅชๆจน Sato29/06/2026, 17:101ApplicationsPoster presentation only
In the decommissioning work at the Fukushima Daiichi Nuclear Power Station (FDNPS), determining the distributions of dose rates and radiation sources, as well as identifying the locations of radioactive hotspots where locally high concentrations of radiation sources exist, is critically important for formulating detailed decontamination plans and minimizing worker exposure. In recent years,...
Go to contribution page -
Laura Luisa Scholl (German Cancer Research Center)29/06/2026, 17:101ApplicationsPoster presentation only
Compared to conventional photon radiotherapy, carbon-ion radiotherapy offers improved targeting accuracy of tumor volumes, but is more sensitive to anatomical changes of the patient that can affect the treatment outcome [1]. To address this, our group has developed a method based on the detection and tracking of charged nuclear fragments using a customized semiconductor-based hybrid pixel...
Go to contribution page -
Regina Oliveira (University of Aveiro)29/06/2026, 17:10ApplicationsPoster presentation only
The easyPET/CT is a novel multimodal preclinical imaging system that combines positron emission tomography (PET) images, which provides molecular-level information, with a photon counting computed tomography (PCCT) modality, which delivers anatomical data of the subject. Both imaging modalities are acquired using the same detector modules, enabling a unified hardware architecture and...
Go to contribution page -
Dr Anna Cimmino (The Extreme Light Infrastructure ERIC, ELI Beamlines Facility)29/06/2026, 17:10ApplicationsPoster presentation only
High-power laser facilities provide a pathway toward compact, tunable muon sources based on laser wakefield accelerated electrons interacting with high-Z converters. Such laser-driven schemes offer unique characteristics compared to conventional or cosmic-ray muon sources, including short pulse duration, intrinsic synchronization, and directional emission, which are attractive for emerging...
Go to contribution page -
Tim Gehrke (Heidelberg University Hospital / German Cancer Research Center)29/06/2026, 17:102ApplicationsPoster presentation only
Introduction:
Go to contribution page
Radiation therapy using protons and heavier ions, referred to as ion-beam therapy in the following, is a highly precise form of radiation therapy. A prerequisite for the best therapeutic outcome is patient-specific treatment planning. It includes the calculation and optimization of the physical dose distribution in the patient and as another key parameter the efficiency of... -
Youngho Seo (Department of Radiology and Biomedical Imaging, University of California, San Francisco, USA)29/06/2026, 17:10ApplicationsPoster presentation only
Quantification of activity levels is a minimum requirement for any radionuclide experiment, including the development of targeted alpha therapies (TATs). Ac-225 (225Ac) is one of the most promising alpha-emitters for TATs. However, the activity levels used for 225Ac experiments are extremely low and cannot be accurately measured by conventional dose calibrators. Dose calibrators are generally...
Go to contribution page -
Dowon Lee (Department of Applied Plasma and Quantum Beam, Jeonbuk National University, Jeonju, Republic of Korea)29/06/2026, 17:101ApplicationsPoster presentation only
Heavy particle therapy utilizes the Bragg peak to precisely deliver radiation doses to tumors, yet real-time verification of the beam range remains a significant challenge. Fast neutron scatter imaging offers a promising solution for in-vivo range verification by detecting highly penetrating secondary neutrons generated during treatment. However, reconstructing high-resolution images from...
Go to contribution page -
Dr Nobuo Suzui29/06/2026, 17:10ApplicationsPoster presentation only
To elucidate selective nutrient transport in plants, we developed a multi-element monitoring system using ultra-compact GAGG detectors ($20 \times 20 \times 43$ mm). Unlike conventional imaging limited to single nuclides, this system enables simultaneous, multi-point tracking of multiple elements at various locations, such as roots and fruits. Validation using PHITS simulations and experiments...
Go to contribution page -
Diletta Borselli (Universita e INFN, Firenze (IT))29/06/2026, 17:10ApplicationsPoster presentation + pitch
The muon absorption radiography technique allows for the generation of average density images of the studied objects by measuring the attenuation of atmospheric muons. This technique is entirely non-invasive; the detectors used, which originate from subnuclear physics, are compact and easily portable. The subjects of study are typically large-scale structures, such as volcanoes, pyramids,...
Go to contribution page -
Hiromi Nakai29/06/2026, 17:10ApplicationsPoster presentation only
Non-invasive imaging of positron-emitting tracers in plants is a powerful tool for elucidating physiological mechanisms. In particular, as a fundamental process for plant growth, photosynthate translocation from source leaves to sink organs has been extensively studied using 11C as a tracer. A previous study focused on photosynthate translocation from a single leaf to fruits in strawberry...
Go to contribution page -
Martin Delcourt (Vrije Universiteit Brussel (BE))29/06/2026, 17:10ApplicationsPoster presentation only
The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) will reach unprecedented instantaneous luminosities of up to $7.5 \times 10^{34}\,\text{cm}^{-2}\text{s}^{-1}$, resulting in significantly increased particle fluxes, radiation levels, and data rates in the innermost detector regions. To operate under these challenging conditions, the current CMS tracking detector will be...
Go to contribution page -
Sung Woo Kwak (Korea Institute of Nuclear Non-proliferation and Control)29/06/2026, 17:10ApplicationsPoster presentation only
Verification of spent fuel in Pressurized Heavy Water Reactors (PHWRs) is a critical task for international nuclear safeguards. Currently, the IAEA and the Korea Institute of Nuclear Nonproliferation and Control (KINAC) utilize the Optical Fiber Radiation Probe System (OFPS) to verify spent fuel bundles at South Korea's three operating CANDU reactors [1]. This verification process involves...
Go to contribution page -
Mr Tomas Fila (Czech Technical University in Prague, Faculty of Transportation Sciences)29/06/2026, 17:10ApplicationsPoster presentation only
The mechanical response of many advanced materials is governed by their internal structure, which often evolves under loading and exhibits pronounced strain-rate dependence. Direct observation of these internal features during deformation is therefore essential, motivating the use of X-ray imaging techniques. However, laboratory-based X-ray imaging of dynamic events is inherently constrained...
Go to contribution page -
423. Phantom-Free Geometry Calibration for Cone-Beam Computed Tomography Using Bayesian OptimizationMr YOUNGHWAN LIM29/06/2026, 17:10ApplicationsPoster presentation only
Accurate scan geometry is essential for high-quality three-dimensional reconstruction in cone-beam computed tomography (CBCT) [1]. However, residual geometric misalignments frequently persist even after careful mechanical alignment, resulting in image degradation such as blurring and structural distortion. Conventional calibration approaches typically rely on dedicated phantoms, limiting their...
Go to contribution page -
Seo Yun Jang29/06/2026, 17:10ApplicationsPoster presentation only
Accurate radionuclide identification and dose assessment are fundamental requirements for radiological safety and environmental monitoring. While data-driven artificial intelligence (AI) models have shown promise in gamma-ray spectroscopy, they frequently rely on purely statistical correlations without an underlying physical framework. This lack of physical grounding often limits their...
Go to contribution page -
Yuta Terasaka29/06/2026, 17:10ApplicationsPoster presentation + pitch
Reliable gamma-ray spectrometry is essential for radiation work management and radioactive waste characterization at the Fukushima Daiichi Nuclear Power Station (FDNPS). However, the measurement requirements vary significantly depending on the target scenario. In high-dose-rate areas inside reactor buildings, portable spectrometers must maintain spectral performance under severe count-rate...
Go to contribution page -
Kyung Taek Lim (Sejong University)29/06/2026, 17:10ApplicationsPoster presentation only
Nuclear facility decommissioning faces a distinct safeguards challenge: control measures are still required even after essential nuclear materials have been removed, and samples collected from dismantling-related areas may require rapid on-site verification to determine whether uranium-bearing residues remain. In this regard, portable HPGe detectors could be well-suited to this role because of...
Go to contribution page -
Seungjun Yoo (School of Mechanical Engineering, Pusan National University)29/06/2026, 17:101ApplicationsPoster presentation only
Riding the wave of advances in artificial intelligence and computer-aided defect inspection, digital X-ray imaging has become essential in industrial applications. Although film-based systems combined with scanners or digitizers can provide high spatial resolution, prolonged acquisition times and the need for human intervention limit throughput. Flat-panel detectors (FPDs), which offer higher...
Go to contribution page -
Anna Mastroberardino (Universita della Calabria e INFN (IT))29/06/2026, 17:10ApplicationsPoster presentation + pitch
We present an autonomous Unmanned Ground Vehicle (UGV) platform for non-invasive environmental radioactivity monitoring, a full account of which has been published in JINST [1]. The system - developed to replace hazardous manual surveys - integrates real-time data acquisition, GPS-tagged geospatial mapping, and AI-driven anomaly detection.
Go to contribution page
The detector module comprises an ENVINET SPD32... -
Boris Vervenne (MEDISIP, Ghent University)29/06/2026, 17:10ApplicationsPoster presentation only
Introduction: Our group is developing the Walk-Through PET, an upright PET scanner that uses two vertical flat-panel detectors to scan patients in a standing position. This geometry increases sensitivity and reduces costs [1] but requires a custom CT component for anatomical imaging and attenuation correction, as opposed to conventional PET/CT scanners where a standard circular CT is put...
Go to contribution page -
Mohammad Heidari29/06/2026, 17:10ApplicationsPoster presentation + pitch
PERCIVAL, the Pixellated Energy-resolving CMOS Imager Versatile and Large, is a 2-megapixel multi-gain soft x-ray detector designed for photon science experiments at Free Electron Laser (FEL) and synchrotron facilities.
Go to contribution page
Cross-talk effects and non-uniformity of dark images limited the performance of the first generation of the sensor, in turn limiting noise performance, frame rate, and dynamic... -
Olga Zormpa (CERN)29/06/2026, 17:10ApplicationsPoster presentation only
Muon reconstruction with high precision and efficiency is a key element of the ATLAS physics program at the LHC, enabling a wide spectrum of measurements and searches. In the first two data-taking periods, the ATLAS Muon Spectrometer (MS) achieved excellent performance, contributing decisively to major results such as precision tests of the electroweak sector, detailed investigations of the...
Go to contribution page -
Ralf Hendrik Menk (Elettra Sincrotrone Trieste)29/06/2026, 17:10ApplicationsPoster presentation + pitch
Spectral and phase-contrast X-ray imaging have emerged as complementary techniques for enhancing image quality and material discrimination. X-ray spectral imaging (XSI) exploits the energy dependence of attenuation, enabling quantitative material decomposition, particularly for high-Z elements via their K-edge signatures. In parallel, X-ray phase-contrast imaging (XPCI) provides sensitivity to...
Go to contribution page -
Christoph Gaรner (Technical University of Munich)29/06/2026, 17:10ApplicationsPoster presentation only
Staining is a standard procedure to enhance contrast in non-invasive imaging, improving the initially low soft tissue contrast and enabling high-resolution structural acquisition [1]. Non-destructive trace element analysis via X-ray fluorescence (XRF) spectroscopy complements this by mapping elemental distributions in biological tissues through characteristic fluorescence signals [2], [3]....
Go to contribution page -
Matthias Knopf29/06/2026, 17:10ApplicationsPoster presentation + pitch
Particle therapy using proton or carbon ions is a form of cancer treatment enabling precise tumor targeting with enhanced biological effectiveness while minimizing damage to surrounding healthy tissue. Successful treatment planning and tumor control depend not only on the total absorbed dose but are also closely linked to the quality of the administered radiation, as quantified by the average...
Go to contribution page -
Isabelle De Bruyn (Universite Libre de Bruxelles (BE))29/06/2026, 17:10ApplicationsPoster presentation only
The CMS Muon system is undergoing significant upgrades in preparation of the High-Luminosity LHC (HL-LHC) operation, in order to maintain excellent performance in unprecedented collision rates. The electronics of the Cathode Strip Chambers (CSCs) are therefore being upgraded, and the new complementary Gas Electron Multiplier (GEM) detectors are being installed. One of the new GEM stations,...
Go to contribution page -
Faiqa Bashir (Universita e INFN Torino (IT))29/06/2026, 17:10ApplicationsPoster presentation + pitch
The CMS experiment at the Large Hadron Collider (LHC) is designed to perform precision measurements and to explore new physics in high energy protonโproton collisions. The performance of its tracking system is essential for the overall physics reach of the experiment, e.g. providing accurate vertex reconstruction and the precise measurement of the momentum of the charged particle. The upcoming...
Go to contribution page -
Karam Kaspar (Ghent University (BE))29/06/2026, 17:10ApplicationsPoster presentation + pitch
The SHiP/NA67 experiment aims to search for feebly interacting GeV-scale new particles and to perform all-flavor neutrino-physics measurements at the HI-ECN3 beam facility at the CERN SPS. The collaboration is currently optimising the experiment's initial configuration for the commissioning and first physics runs of 2032-2033.
Go to contribution page
The detector subsystems comprise a few large-area instruments: for... -
Stefano Capra (University of Milan, INFN (Milan))29/06/2026, 17:10ApplicationsPoster presentation only
Decay spectroscopy with radioactive ion beams (RIBs) is a key tool for investigating nuclear structure far from stability and for constraining nucleosynthesis processes. Experiments at FAIR, particularly within the DESPEC setup, rely on highly segmented active stoppers such as AIDA to correlate ion implantation with subsequent ฮฒ decays. However, present systems based on double-sided silicon...
Go to contribution page -
Jens Erik Brucken (University of Helsinki (FI))29/06/2026, 17:10ApplicationsPoster presentation only
The Minimum Ionising Particle Timing Detector (MTD) is a new addition to the apparatus of the CMS experiment for the High Luminosity phase of the Large Hadron Collider (HL-LHC) starting in 2030. Providing precise time-of-arrival information will significantly increase the efficiency of the CMS experiment in reconstructing individual proton-proton collisions in the high โpile-upโ environment of...
Go to contribution page -
Jasmin Burke (Rapiscan)29/06/2026, 17:10ApplicationsPoster presentation only
The security industry uses a wide range of detector technologies for various applications, primarily cargo and vehicle inspection and baggage and parcel inspection. This discussion focuses specifically on cargo and vehicle inspection. A wide range of detectors are required to be able to detect the vast range of anomalies and threats that can appear in cargo and vehicles. Two primary x-ray...
Go to contribution page -
Yuta Miyoshi (Takasaki Advanced Radiation Research Institute, National Institutes for Quantum and Radiological Science and Technology)29/06/2026, 17:10ApplicationsPoster presentation only
Radioisotope (RI) tracers are powerful tools for noninvasively visualizing and quantifying the translocation, allocation, and accumulation of substances, and are widely used not only in medicine and materials science but also in agricultural research. In plant studies, imaging using RI tracers such as ยนยนC, ยนยณN, and ยฒยฒNa combined with positron-emitting tracer imaging system (PETIS) enables...
Go to contribution page -
Matthieu Boone29/06/2026, 17:10ApplicationsPoster presentation only
At Eindhoven University of Technology, a tabletop x-ray source based on inverse Compton scattering (ICS) has recently been commissioned. In the ICS process monochromatic x-rays are produced by colliding relativistic electron bunches with intense laser pulses. This compact and tunable source holds the promise of a performance in between small-scale x-ray tubes and large-scale synchrotron light...
Go to contribution page -
Maria Martisikova (German Cancer Research Center)29/06/2026, 17:10ApplicationsPoster presentation + pitch
MOTIVATION:
Go to contribution page
Carbon-ion radiotherapy is a powerful modality for the precise treatment of tumors located deep within the body, particularly when they are situated in close proximity to critical structures such as the brainstem, spinal cord, or optic pathways. The advantageous sharp focusing of the treatment dose to the tumor, however, results in a high sensitivity to beam range uncertainties... -
Jiri Volny29/06/2026, 17:10ApplicationsPoster presentation only
X-ray radiography visualizes the objectโs internal structure through the absorption contrast that is given by the object's variations in density and composition. In comparison, X-ray diffraction (XRD) probes the objects crystal structure itself. XRD is constructive interference of elastically scattered X-rays on the electron shell of the constituent atoms of the crystal where the position of...
Go to contribution page -
Karel DesplenterApplicationsPoster presentation only
Hyperspectral Xโray imaging has the potential to enable quantitative material discrimination, chemical decomposition, and concentration measurements based on spectral attenuation behavior.
Go to contribution page
We investigate how recorded X ray beam spectra are modified by material attenuation and how detector and processing related effects influence spectrally resolved attenuation measurements in hyperspectral...
Choose timezone