19–21 Nov 2014
CERN
Europe/Zurich timezone

Characterization after neutron irradiation of Silicon Diodes for the CMS High Granular Calorimeter (HGCAL)

19 Nov 2014, 14:55
20m
500/1-001 - Main Auditorium (CERN)

500/1-001 - Main Auditorium

CERN

503-1-001 (Council Chamber) on 19th Nov ; 500-1-001(Main auditorium) on 20th in the morning and 4-3-006 (TH auditorium) in the afternoon; 500-1-001(Main auditorium) on 21st Nov.
400
Show room on map

Speaker

Esteban Curras Rivera (Universidad de Cantabria (ES))

Description

The CMS collaboration is planning to upgrade the forward calorimeters as these will not be sufficiently performant with the expected HL-LHC (High Luminosity LHC) conditions. One of the proposed calorimeter options is the High Granularity Calorimeter (HGC). It is realized as a sampling calorimeter with layers of silicon detectors that feature very high longitudinal and lateral granularities and a coarser segmentation backing hadronic calorimeter based on scintillators as active material. For the electromagnetic calorimeter (EE) 420m2 of silicon detectors and for the Front Hadronic calorimeter (FH) 250m2 of silicon detectors with a total of 5.1M channels are anticipated. The sensors are realized as pad detectors of a size in the order of 1 cm2 with an active thickness between 100 and 300 um depending on the position respectively the expected radiation levels. We present our first results after irradiation of 300µ, 200µ and 100µ n-on-p and p-on-n devices that have been made up to fluxes of 1.5E16 n/cm2 at Ljubljana and have been measured at Hamburg.

Author

Esteban Curras Rivera (Universidad de Cantabria (ES))